• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
陈兵,李群,袁晓冬,杨洪耕,罗珊珊.电能质量监测装置校验信号实现新方法[J].电测与仪表,2014,51(12):.
CHEN BING,LI QUN,YUAN XIAODONG,YANG HONGGENG,LUO SHANGSHANG.A New Method of Calibration Signal Implementation for Power Quality Monitoring Devices[J].Electrical Measurement & Instrumentation,2014,51(12):.
电能质量监测装置校验信号实现新方法
A New Method of Calibration Signal Implementation for Power Quality Monitoring Devices
DOI:
中文关键词:  电能质量监测装置  相似度原理  异构等效  校验信号  同步
英文关键词:Power Quality Monitoring Devices  Similarity Theory  Heterogeneous Equivalence  Calibration Signal  Synchronous
基金项目:国家电网公司重点科技项目
              
作者中文名作者英文名单位
陈兵CHEN BING江苏省电力公司电力科学研究院
李群LI QUN江苏省电力公司电力科学研究院
袁晓冬YUAN XIAODONG江苏省电力公司电力科学研究院
杨洪耕YANG HONGGENG四川大学电气信息学院
罗珊珊LUO SHANGSHANG江苏省电力公司电力科学研究院
摘要点击次数: 2204
中文摘要:
      提出基于相似度原理异构等效的电能质量监测装置校验信号实现的新方法,通过将监测装置采样信号序列与标准源输出信号序列进行时序平移相似度计算,分析校验信号同步方法和构成;研究异构校验信号输出实现,给出监测装置整点采样和随机采样时异构校验信号输出实现方法。开发了电能质量监测装置校验信号实现软件系统,对监测装置精度进行校准验证,校验结果表明运用此方法能彻底解决标准源输出信号序列与监测装置采样序列无法同步、相邻校准信号之间存在相互干扰等问题,有效的提高了对装置精度检验的准确度和可靠性,对提高电网和用户电能质量监测水平,以及电能质量监测装置技术提升和产业发展起到了积极的促进作用。
英文摘要:
      A new method of calibration signal implementation for power quality monitoring devices based on heterogeneous equivalence of similarity theory is proposed in the paper. Timing-shift similarity calculation between the sampling signal sequence of the monitoring device and the output signal sequence of standard source is carried out, to analyze calibration signal synchronization method and its composition. Output method of heterogeneous calibration signal in the case of the whole point sampling and random sampling of the monitoring device is studied. In addition, the calibration software about power quality monitoring devices is developed to measure accuracy of the devices, and the calibration results show that the questions of asynchronous between the sampling signal of the monitoring device and the output signal of standard source, and mutual interference between adjacent calibration signals are completely solved. This greatly improves the accuracy and reliability of detecting the monitoring device, improves the level of monitoring grid and user power quality, and has played a positive role in upgrading and promoting the technology and industrial development of power quality monitoring devices.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司