杨帅,陈向群,赵丹,徐征,谢晓骞,郭丁荧,杨方,张璨辉.关口电能计量故障监测报警装置及主站研究[J].电测与仪表,2014,51(13):.
YANG Shuai,CHEN Xiang-qun,ZHAO Dan,XU Zheng,XIE Xiao-qian,GUO Ding-ying,YANG Fang,ZHANG Can-hui.A Research on the Alarming instrument and Master Station of the Gateway Energy Measuring Failure[J].Electrical Measurement & Instrumentation,2014,51(13):.
关口电能计量故障监测报警装置及主站研究
A Research on the Alarming instrument and Master Station of the Gateway Energy Measuring Failure
DOI:
中文关键词:  关口计量故障  102通信规约  多元电量追补
英文关键词:failure  monitoring of  gateway energy  measurement, 102 Communication  Protocol, multi-electricity  compensation
基金项目:
                       
作者中文名作者英文名单位
杨帅YANG Shuai国网湖南省电力公司计量中心
陈向群CHEN Xiang-qun国网湖南省电力公司计量中心
赵丹ZHAO Dan国网湖南省电力公司计量中心
徐征XU Zheng国网山东省电力公司
谢晓骞XIE Xiao-qian国网湖南省电力公司
郭丁荧GUO Ding-ying国网湖南省电力公司计量中心
杨方YANG Fang国网湖南省电力公司计量中心
张璨辉ZHANG Can-hui国网湖南省电力公司计量中心
摘要点击次数: 2422
中文摘要:
      本文针对近年来频发的省级关口计量故障,研究了一套计量故障事件监测及报警系统,并给出了具体的软硬件实现。该系统通过扩展102通信规约,利用故障监测终端实时采集关口电能表失压、失流、断相以及不对称功率等事件,通过PSTN或LAN传输至主站与EMS/SCADA、用电信息采集系统进行故障核实,并采用SMS短信、IMAP邮件、页面警示方式提醒运维人员进行及时处理。此外,本文还介绍了一种多元电量追补技术,根据不同的故障方式,自动生成电量追补公式,通过母线电量、变压器三侧电量、线路对侧电量等多种平衡措施对追补电量进行验证和追补。
英文摘要:
      As recurrent failures in gateway measurement over recent years, this thesis researches on the measurement monitoring and alarming of a system with specific and viable software and hardware. By extending the 102 Communication Protocol of Central China, this system makes use of the failure monitoring terminal to real time collect the events such as voltage lose, current lose, TV failure and power imbalance, transmits them to the master station through PSTN or LAN, and make use of EMS/SCADA and the electrical energy acquistion system to verify the failures. Then by means of SMA massage, IMAP mail and online warning, the system reminds the OAM staff to process in time. Further more, a way of multi-electricity compensation is introduced. Electricity compensation formula is automatically generated according to different failure, and the compensated electricity will be verified and compensated by the balance measures such as the electricity of the busbar, the 3 sides electricity of the main transformer and the electricity of the opposite wires.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司