• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
陈林,杨俊华,陈思哲,吴捷.非对称负载下矩阵变换器改进型PI重复控制[J].电测与仪表,2015,52(4):.
CEHN Lin,YANG Jun-Hua,CEHN Si-Zhe,WU Jie.Research on Matrix Converter in Unsymmetrical Load with Improved Repetitive and PI Control Strategy[J].Electrical Measurement & Instrumentation,2015,52(4):.
非对称负载下矩阵变换器改进型PI重复控制
Research on Matrix Converter in Unsymmetrical Load with Improved Repetitive and PI Control Strategy
DOI:
中文关键词:  矩阵变换器  PI  重复控制  非对称负载  Park变换
英文关键词:Matrix converter  PI  Repetitive control  Unsymmetrical load  Park transformation
基金项目:国家自然科学基金项目(51377026); 广东省教育厅专项重点实验室 (IDSYS200701). 广东省自然科学基金项(S2012040007895).
           
作者中文名作者英文名单位
陈林CEHN Lin广东工业大学 自动化学院
杨俊华YANG Jun-Hua广东工业大学 自动化学院
陈思哲CEHN Si-Zhe广东工业大学 自动化学院
吴捷WU Jie华南理工大学 电力学院
摘要点击次数: 1852
中文摘要:
      针对非对称负载下矩阵变换器(MC)重复控制与PI控制的不足,提出改进的复合控制策略,有效改善输出电压质量。通过建立d-q坐标系下的MC数学模型,分析系统稳定性条件与扰动抑制特性,设计控制器;因重复控制器的内模包含一个延迟环节,信号调节显著滞后。在分析Park变换前后谐波分布特点基础上,采用双序Park变换,将相坐标系下的谐波变换为d-q坐标系下的3倍次谐波,进而改进内模,减少控制系统调节时间,同时可保证谐波抑制性能。仿真结果表明,所提控制方案具有良好的扰动抑制特性和快速调节能力,可有效解决三相输出电压不平衡问题。
英文摘要:
      In order to solve the control problems of matrix converter(MC) in unsymmetrical load with PI control or repetitive control (RC) strategy, a combined scheme of PI and RC method was proposed, and the quality of output voltage could be effectively promoted. The compound controller was designed by establishing the mathematical model of MC in d-q coordinates, and analyzing the stability conditions as well as the characteristics of disturbance attenuation of MC system. As a delay link was included in the internal model of the repetitive controller, an obvious lag existed in signal regulation process. Based on analyzing the harmonic features around park transformation, the harmonics in phase coordinate system was converted to 3 times harmonics in d-q coordinates by park transformation in double sequences. The internal model was improved, and the settling time of the compound controller could be reduced without affecting the performance of harmonic suppression. The simulative results indicate that the improved compound controller has a good property in the regulation capability and the disturbance suppression, the unbalanced problem of three-phase output voltage could be effectively resolved.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司