王建元,鞠默欣,徐志璇,鞠默然.基于HHT小电流接地故障选线与在线故障定位方法[J].电测与仪表,2014,51(15):.
WANG Jian-yuan,JU Mo-xin,XU Zhi-xuan,JU Mo-ran.A Method of Fault Line Selection and Fault Location Online in Neutral Point Ineffectively Grounded Power System Based on HHT[J].Electrical Measurement & Instrumentation,2014,51(15):.
基于HHT小电流接地故障选线与在线故障定位方法
A Method of Fault Line Selection and Fault Location Online in Neutral Point Ineffectively Grounded Power System Based on HHT
DOI:
中文关键词:  HHT  小电流接地系统  故障选线  在线故障定位
英文关键词:HHT, Neutral point ineffectively grounded power system, Fault line selection, Fault location online
基金项目:
           
作者中文名作者英文名单位
王建元WANG Jian-yuan东北电力大学
鞠默欣JU Mo-xin东北电力大学
徐志璇XU Zhi-xuan东北电力大学
鞠默然JU Mo-ran吉林大学
摘要点击次数: 2564
中文摘要:
      使用电力电缆进行电力传输已经逐渐被推广,配电系统出线线路因而多由架空线、电缆和电缆-架空线混合线路构成,在小电流接地系统发生单相接地故障时,由于系统仍可运行1-2小时,这就要求在不断电的情况下,实现故障选线,并对故障进行定位。本文提出一种基于HHT小电流接地故障选线与在线故障定位的方法,利用奇异性检测法判断各线路在故障时刻的极性,实现故障选线,在线路参数未知的情况下,采用合闸时产生的操作过电压行波在线测量行波波速,单相接地故障发生后,将母线接收到的电压信号进行相模变换,采用具有很强完备性和自适应性的HHT处理变换后的模量,寻找行波瞬时频率突变的时刻,并运用单端测距法实现对架空线、电缆和电缆-架空线混合线路故障定位。最后,对算例进行数值仿真,仿真结果验证了该方法的可行性和实用性。
英文摘要:
      Power cable for power transmission has been gradually extended. The outlet lines in distribution system therefore are more constituted with overhead lines, cables and hybrid lines. The system can be still running 1-2 hours when single phase to earth fault occurs, which requires the location of the fault is detected in the case of UPS. A method of power cable fault location online in neutral point ineffectively grounded power system based on HHT is proposed in this paper. Singularity detection method by which fault line selection can be achieved is used to determine the polar of each line at fault time. Under the condition that the parameters of lines are unknown, the velocity of traveling wave in cable can be measured by the use of switching overvoltage wave which is generated when the closing occurs. The modulus can be obtained by the method of phase-mode transformation when single phase to earth fault happens. HHT, which has a strong completeness and adaptability, is used to process the non-stationary modulus and find the mutations moments of instantaneous frequency. Then the location of line fault is determined by one-terminal fault location method. Finally, the digital simulation results of an example show the effectiveness and practicability of this method.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司