龙兆芝,李文婷,鲁非,宗贤伟.溯源用低阻抗冲击电压标准波源[J].电测与仪表,2015,52(4):.
Long Zhaozhi,liwenting,lufei,zongxianwei.A Low Impedance impulse voltage Calibrator used in Traceability[J].Electrical Measurement & Instrumentation,2015,52(4):.
溯源用低阻抗冲击电压标准波源
A Low Impedance impulse voltage Calibrator used in Traceability
DOI:
中文关键词:  IEC标准  冲击电压标准波源  不确定度  测量值  短时稳定性  长时稳定性  带载能力
英文关键词:IEC standard  impulse voltage standard calibrator  uncertainty  measured value  short term stability  long term stability  load capacity.
基金项目:
           
作者中文名作者英文名单位
龙兆芝Long Zhaozhi中国电力科学研究院计量研究所
李文婷liwenting中国电力科学研究院计量研究所
鲁非lufei国网湖北省电力公司电力科学研究院
宗贤伟zongxianwei中国电力科学研究院计量研究所
摘要点击次数: 2245
中文摘要:
      本文介绍了可产生IEC60060-1中规定的雷电全波的低阻抗冲击电压标准波源的原理及其不确定度评定。冲击电压标准波源为小型的Max发生器,其电压峰值Up、波前时间T1、波尾时间T2都可以根据脉冲形成回路的元器件参数计算得到。该标准波源的输出电压波形峰值为10V-1000V,输出波形参数不确定度(置信概率95%,包含因子k=2)为:峰值UUp:5×10-4,波前时间UT1:4×10-3,半峰值时间UT2: 4×10-3,。采用PTB校准过的14Bit数字记录仪测量低阻抗标准的输出波形,并将测量结果与理论计算值进行比较。连续重复20次,最大相对标准偏差为2.7×10-4。在六个月内各电压点峰值长时稳定性在0.2‰内。负载分别为7.95kΩ和1MΩ,理论计算波形参数的区别与测量结果吻合。表明该低阻抗冲击电压标准波源既可校核数字记录仪也可校准电阻分压器。
英文摘要:
      The principle and uncertainty of a low impendence standard calibrator that produces full lighting impulse is described. The calibrator is a small MAX generator, The peak value Up , front timeT1, and time to half value T2of the generated impulse are calculated from the calibrated values of the components of the impulse forming network. The operating voltage range of the calibrator is from 10V to1000 V. The expand uncertainty of Up, T1, T2 is 5×10-4, 4×10-3 , 4×10-3 respectively at 95% confidence level with a coverage factor of 2. The deviation for the peak value of measured value and set value is from -0.5‰ to 0.2‰, for front timeT1 from -1.5‰ to 2.5‰ and for time to half value T2 from -0.6‰ to 0.6‰. The accuracy for the impulse peak value is ±1‰ and for the time parameters, less than ±1%. Repeated 20 times, the max standard deviation is 2.7×10-4. During six months the long term stability is less than 0.2‰. The load is 7.95kΩ compared to 1MΩ, the differentials of measured value for Up、T1、T2 isagreement with of calculated value. The experimental results show that the low impedance calibrator is not only can be used as the primary reference of impulse voltages for calibration of digital record but also can used to calibrating the impulse voltage divider.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司