夏珩轶,唐跃林,杨华忠,陈晓聪,汪力,魏钢,赵仲勇,李成祥,陈昱,姚陈果.暂态过电压检测电力变压器绕组匝间短路故障[J].电测与仪表,2015,52(12):.
XIA Heng-yi,TANG Yue-lin,YANG Huazhong,CHEN Xiao-cong,WANG Li,WEI Gang,ZHAO Zhong-yong,LI Cheng-xiang,CHEN Yu,YAO Chen-guo.Detecting Shorted Turns Failure on the Windings of Power Transformer by Transient Overvoltage[J].Electrical Measurement & Instrumentation,2015,52(12):.
暂态过电压检测电力变压器绕组匝间短路故障
Detecting Shorted Turns Failure on the Windings of Power Transformer by Transient Overvoltage
DOI:
中文关键词:  绕组变形  暂态过电压  匝间短路故障  试验研究
英文关键词:Transformer winding deformation, transient overvoltage, shorted turns failure, test research
基金项目:
                             
作者中文名作者英文名单位
夏珩轶XIA Heng-yi重庆电力公司检修分公司
唐跃林TANG Yue-lin重庆电力公司检修分公司
杨华忠YANG Huazhong重庆电力公司检修分公司
陈晓聪CHEN Xiao-cong重庆电力公司检修分公司
汪力WANG Li重庆电力公司检修分公司
魏钢WEI Gang重庆电力公司检修分公司
赵仲勇ZHAO Zhong-yong重庆大学输配电装备与系统安全及新技术国家重点实验室
李成祥LI Cheng-xiang重庆大学输配电装备与系统安全及新技术国家重点实验室
陈昱CHEN Yu重庆大学输配电装备与系统安全及新技术国家重点实验室
姚陈果YAO Chen-guo重庆大学输配电装备与系统安全及新技术国家重点实验室
摘要点击次数: 1688
中文摘要:
      变压器在运行过程中,其内部初始故障最终有可能发展成灾难性事故,导致设备停运和电网停电,绕组变形被认为是变压器内部的最主要的故障之一。文本利用变压器运行时遭受过电压信号冲击的特性,提出暂态过电压可实现绕组变形故障的在线检测。首先,介绍了该方法的基本原理,在此基础上搭建了验证性试验平台,进行了匝间短路故障模拟试验。试验结果表明,该方法在一定程度上可实现绕组匝间短路故障的检测,具有一定的参考价值。
英文摘要:
      The initial faults inside transformer would eventually develop into catastrophic failure during its operation, which could result in the outage of equipment and entire network. Winding deformation is considered to be the most common faults inside transformer. As power transformer is under the impact of overvoltage during its operation, the method of transient overvoltage could be used to realize online detecting transformer winding deformation is proposed in this paper. Firstly, the basic principle of this method is developed, then a verifying test platform is set up, and the simulation test of shorted turns failure is completed. The test result shows that the proposed method could realize detecting shorted turns failures of transformer winding to a certain extent, and this method has a certain reference value. .
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司