The function of λ/4 wave plate in fiber optical current transformer (FOCT) is introduced. The fabrication factors of λ/4 wave plate were studied and the temperature drift of λ/4 wave plate at all temperature conditions were analyzed. The two methods of material selection and temperature compensation technology, which can reduce the temperature drift, were discussed. And its feasibility was verified by experiment.