• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
刘鹍,邹旭东,钟贞,刘建昆,何实,王兵,汪建谊,夏冰.用电信息采集终端通信硬件端口自动化接驳和本地通信方案的研究与实现[J].电测与仪表,2015,52(2):.
Liu Kun,Zou Xu-dong,Zhong Zhen,Liu Jian-kun,He Shi,Wang Bing,Wang Jianyi,Xia Bing.The electric energy data acquisition terminal communication hardware portautomatic feeder and local communication scheme Research and Implementation[J].Electrical Measurement & Instrumentation,2015,52(2):.
用电信息采集终端通信硬件端口自动化接驳和本地通信方案的研究与实现
The electric energy data acquisition terminal communication hardware portautomatic feeder and local communication scheme Research and Implementation
DOI:
中文关键词:  采集终端  自动化接驳  GPRS/CDMA  以太网  本地通信(RS-232)  RS-485  
英文关键词:Acquisition  terminal, GPRS/CDMA,Ethernet, The  local communication (RS-232), RS–485
基金项目:
                       
作者中文名作者英文名单位
刘鹍Liu Kun四川省电力公司计量中心
邹旭东Zou Xu-dong四川省电力公司计量中心
钟贞Zhong Zhen成都理工大学
刘建昆Liu Jian-kun四川省电力公司计量中心
何实He Shi四川省电力公司计量中心
王兵Wang Bing深圳市科陆电子科技股份有限公司
汪建谊Wang Jianyi深圳市科陆电子科技股份有限公司
夏冰Xia Bing深圳市科陆电子科技股份有限公司
摘要点击次数: 2487
中文摘要:
      目前,电力用户用电信息采集终端的功能检测主要采用人工插接RS-232端口,建立检测装置与终端本地通信的方式为主,虽然该方式成熟可靠,但存在检测效率低下和难以实现自动化操作等问题。因此,本文提出扩展采集终端RS-485抄表辅助端子功能,用以实现RS-485抄表口为采集终端本地通信口,开启RS-485辅助端子本地通信和参数设置功能的方案。该项研究巧妙解决了目前制约采集终端通信硬件端口自动化接驳和同时实现本地通信的技术瓶颈,因此,具有重要的突破性意义,也为推动实现采集终端的自动化检测系统定型和推广应用提供了可靠的解决方案。
英文摘要:
      At present, the power user electric energy data acquisition terminal function detection by manual inserting the RS-232 port, a detecting device and a terminal local communications, although it is mature and reliable, but there exists the problem of low detection efficiency and difficult to realize automation etc.. Therefore, this paper extends the acquisition terminal RS-485 meter auxiliary terminal function, to realize RS-485 meter reading for the acquisition terminal local communication port, open the RS-485 auxiliary terminal local communication and parameter setting function scheme. The study resolves currently restricting the acquisition terminal communication hardware port connection and realize automation technology bottleneck, the local communication and therefore, has the important breakthrough, but also to promote the realization of automated detection system of the collection terminal type and application provides a reliable solution.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司