• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
曹晶,杨毅,曾祥君,刘慧琼.单-多端行波组合的配电网单相接地故障定位方法[J].电测与仪表,2015,52(16):.
CAO jing,yangyi,ZENG Xiang-jun,LIU Hui-qiong.A single-phase-ground fault location combined method for distribution networks based on single-termina and multi-termina travelling wave[J].Electrical Measurement & Instrumentation,2015,52(16):.
单-多端行波组合的配电网单相接地故障定位方法
A single-phase-ground fault location combined method for distribution networks based on single-termina and multi-termina travelling wave
DOI:
中文关键词:  配电网  单相接地  多端行波  单端行波  故障定位
英文关键词:distribution  networks, single-phase-ground, multi-terminal  traveling wave, single-terminal  traveling wave, fault  location
基金项目:国家自然科学基金项目(面上项目,重点项目,重大项目)
           
作者中文名作者英文名单位
曹晶CAO jing长沙理工大学 智能电网运行与控制湖南省重点实验室
杨毅yangyi长沙理工大学 智能电网运行与控制湖南省重点实验室
曾祥君ZENG Xiang-jun长沙理工大学 智能电网运行与控制湖南省重点实验室
刘慧琼LIU Hui-qiong长沙理工大学 智能电网运行与控制湖南省重点实验室
摘要点击次数: 1772
中文摘要:
      针对配电网网络结构复杂,分支多,故障定位困难,提出了一种单端、多端相结合的配电网单相接地故障行波定位方法。首先根据配电网拓扑结构,依据最优配置原则,选取需安装行波定位装置的配变终端,然后通过奇异值分解(SVD)对故障行波信号进行检测,应用多端行波故障选线算法判别障故障线路。在此基础上,各行波定位装置采用小波波形相关性方法,检测两个相关反射波时间差进行单端行波测距,并进行信息融合,得出最终定位结果。仿真结果表明,该方法在某台定位装置失灵、时间记录错误时也能实现配电网的故障准确定位,具有很强的容错性和较高的定位精度。
英文摘要:
      As the actual complex disturibution network has many branches , it is very diffcult to find the fault point .A single-phase-ground fault location method based on single-terminal traveling wave and multi-terminal traveling wave is put forward. According to the optimal allocation principle, for the structure of the distribution network, there are only several location equipment is installed in disturibution grid. singular value decomposi tion (SVD) is applied to detect the signals.The fault line is selected by using multi-terminal traveling wave fault line selection algorithm.After that a single-terminal fault location algorithm that uses wavelet transformal and graphic correlation to detect the time difference of wave heads is proposed. By using information fusion, the final results orientation is obtained. The accuracy of fault location still can be guaranteed even though a locating device breaks down, records the wrong time date in disturibution systems. Tbe results of simulation indicates that this algorithm has the strong fault tolerance and high fault location accuracy.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司