张义龙,李立学,郑益慧,王昕,于建友,杨景波.电缆接头局部放电电磁仿真与多传感器联合检测[J].电测与仪表,2016,53(9):.
ZHANG Yi-long,LI Li-xue,ZHENG Yi-hui,WANG Xin,YU Jian-you,YANG Jing-bo.Electromagnetic Simulation of Partial Discharge in XLPE Cable Joint and Multi Sensor Joint Detection[J].Electrical Measurement & Instrumentation,2016,53(9):.
电缆接头局部放电电磁仿真与多传感器联合检测
Electromagnetic Simulation of Partial Discharge in XLPE Cable Joint and Multi Sensor Joint Detection
DOI:
中文关键词:  电缆接头  局部放电  电磁仿真  高频  超高频  联合检测
英文关键词:cable joint, partial discharge, electromagnetic simulation, high frequency, ultra high frequency, joint detection
基金项目:国家自然科学基金(60504010),国家高新技术863发展计划(2008AA04Z129),上海市自然科学基金(14ZR1421800),流程工业综合自动化国家重点实验室开放课题基金资助
                 
作者中文名作者英文名单位
张义龙ZHANG Yi-long上海交通大学电工与电子技术中心
李立学LI Li-xue上海交通大学电工与电子技术中心
郑益慧ZHENG Yi-hui上海交通大学电工与电子技术中心
王昕WANG Xin上海交通大学电工与电子技术中心
于建友YU Jian-you国网吉林省电力公司白山供电公司
杨景波YANG Jing-bo国网吉林省电力公司白山供电公司
摘要点击次数: 1673
中文摘要:
      目前对于已敷设的电力电缆的局部放电检测,单一的采用高频电流法或超高频法都易受到现场干扰信号的影响。因此,为提高检测的有效性和准确度,本文采用高频电流法和超高频法联合检测的方法,通过对比两种检测结果中是否同时存在脉冲信号来相互鉴别去除干扰信号。对于其中的超高频检测,为了克服内置式传感器在已投运电缆中无法应用的局限性,本文采用了外置式传感器。其使用时面临着信号辐射出来及在空气传播过程中强度会有较大衰减的情况,针对这一情况结合用于三相交叉互联的电缆中间接头的屏蔽层是断开的这一特征,本文进行了建模仿真,验证了采用外置式传感器的可行性,得到了信号最强的传感器最佳安装位置。最后利用研制的传感器进行了现场实测,验证了仿真结论,并证明了联合检测的方法能够很好的甄别干扰信号与真正的局部放电信号。
英文摘要:
      At present, taking a monolithic approach of high frequency current transformer (HFCT) method or ultra high frequency (UHF) method is susceptible for partial discharge detection in the power cable. Joint detection of HFCT method and UHF method is used to improve the effectiveness and accuracy of cable partial discharge detection. In the joint method, the impulse interference is removed by analyzing the simultaneity of two detection results of the pulse signal. The built-in sensor in UHF method cannot be applied to measure partial discharge of the cable in operation, so the external sensor is presented in this paper. In the process of using external sensor, the signal intensity has great attenuation after radiation out of cable joint and propagation in the air. For 110kV three-phase cross-bonded cable, the shield of cable joint is disconnected. Considering that, electromagnetic simulation is conducted to verify the feasibility of using external sensor and find the optimal placement. Finally, the sensors are used in on-site detection. The simulation results are proved to be valid and the joint detection is able to identify the interference signal and real partial discharge signal.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司