• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
周香珍,周航,曲锐,吴泰宇,张顺,朱宏超.考虑转矩失衡的双馈感应风电机组低电压穿越控制研究[J].电测与仪表,2015,52(20):.
ZHOU Xiang-zhen,ZHOU Hang,QU Rui,WU Tai-yu,Zhang Shun,Zhu Hong-chao.Research of Low Voltage Ride-through for Doubly Fed Induction Generator based Wind Turbines in Consideration of Unbalance of Rotor Torques[J].Electrical Measurement & Instrumentation,2015,52(20):.
考虑转矩失衡的双馈感应风电机组低电压穿越控制研究
Research of Low Voltage Ride-through for Doubly Fed Induction Generator based Wind Turbines in Consideration of Unbalance of Rotor Torques
DOI:
中文关键词:  双馈感应风电机组  低电压穿越  主动式Crowbar保护  转矩失衡
英文关键词:Doubly fed induction generator-based wind turbine  Low voltage ride-through  Active crowbar protection  Unbalance of rotor torques
基金项目:
                 
作者中文名作者英文名单位
周香珍ZHOU Xiang-zhen南京理工大学泰州科技学院
周航ZHOU Hang国网黑龙江省电力有限公司七台河供电公司
曲锐QU Rui广东电网公司佛山供电局
吴泰宇WU Tai-yu国网吉林省电力有限公司松原供电公司
张顺Zhang Shun江苏省电力公司检修分公司
朱宏超Zhu Hong-chao国网辽宁省电力有限公司本溪供电公司
摘要点击次数: 1835
中文摘要:
      目前双馈感应风电机组(DFIG)主要通过配备主动式Crowbar保护来实现低电压穿越(LVRT),由于电网扰动将打破风电机组原有的转矩平衡条件,由此可能导致风电机组转子加速至超速保护动作值,触发超速保护动作,致使风电机组发生超速脱网,无法实现故障穿越。本文分析了dq坐标系下DFIG的数学模型和功率解耦控制原理,基于PSCAD/EMTDC仿真平台搭建的DFIG联网仿真系统,仿真分析了因转矩失衡导致机组超速脱网的LVRT失败过程,表明机电暂态过程对机组LVRT有重要影响。继而提出一种故障期间重启转子变流器、恢复机组功率控制的改进LVRT控制策略,仿真结果表明了改进控制策略的有效性。
英文摘要:
      The Crowbar circuit is put into operation to implement low voltage ride through (LVRT) for doubly fed induction generator-based wind turbine (DFIG) during the fault. If a disturbance triggers the Crowbar circuit, it will lead to unbalance of rotor torques of wind generator. The rotor speed may exceed limitation, as a result, the over-speed protection would be triggered and wind generators tripping off from grid. In this paper, the mathematical model of DFIG under dq synchronous rotating coordinate system and the theory of decoupling control of active power and reactive power are analyzed. Based on the simulation system of PSCAD/EMTDC, the DFIG system connected with grid is established. The transient process of DFIG’s over-speed trip-off caused by torque unbalance is simulated and analyzed, which has been showed that mechanical and electric transient has had a major impact on LVRT ability. Further, the traditional LVRT scheme is improved on the basis of restarting rotor-side converter and recovering the control of power during symmetrical grid fault. The simulation results showed that the improved scheme is helpful to enhance the ability of LVRT for DFIG.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司