王旭东,曹宝夷,梁栋,王守相.配电终端对配电系统可靠性的DSRATU分析方法[J].电测与仪表,2015,52(24):.
WANG Xu-dong,Cao Baoyi,LIANG Dong,WANG Shou-xiang.DSRATU Method on Distribution System Reliability Analysis with Distribution Terminal Units[J].Electrical Measurement & Instrumentation,2015,52(24):.
配电终端对配电系统可靠性的DSRATU分析方法
DSRATU Method on Distribution System Reliability Analysis with Distribution Terminal Units
DOI:
中文关键词:  配电系统  可靠性分析  终端  故障关联开关集  最短路
英文关键词:distribution  system, reliability  analysis, terminal  unit, fault  relevant switches  set, shortest  path
基金项目:国家高技术研究发展计划(863计划);国家自然科学基金项目(面上项目,重点项目,重大项目)
           
作者中文名作者英文名单位
王旭东WANG Xu-dong国网天津市电力公司电力科学研究院
曹宝夷Cao Baoyi国网天津市电力公司东丽供电分公司
梁栋LIANG Dong天津大学智能电网教育部重点实验室
王守相WANG Shou-xiang天津大学智能电网教育部重点实验室
摘要点击次数: 1933
中文摘要:
      智能配电网的发展带来配电自动化一遥、二遥、三遥配电终端的大量应用,尤其三遥的装设使开关可遥控,从而对配电系统的可靠性情况产生较大影响。各种典型配电自动化方案实施后的配电网可靠性分析对于准确体现配电自动化的效果尤为重要。本文提出了一种新的含一遥、二遥、三遥终端配电系统的可靠性分析方法(DSRATU),定义了故障关联开关集的概念,可直接定位影响负荷停电时间的开关,并以该开关的动作时间作为故障隔离时间,体现了不同终端类型对于可靠性的影响,此外结合图论的最短路径算法对具有遥控功能的三遥终端安装位置对配电网可靠性影响进行了单独处理。采用RBTS母线2可靠性分析算例验证了所提算法的有效性,所提算法直观清晰,计算复杂度低、满足工程实际需求。
英文摘要:
      The development of the smart distribution system results in wide installation of distribution terminal units into the distribution system, especially the installation of three remote terminal units that make switches controllable, which greatly affects the reliability of the distribution system. Distribution system reliability analysis method under different types of distribution automation scheme is especially important to accurately reflect the effect of distribution automation. This paper proposes a new method of distribution system reliability analysis with multiple distribution terminal units, which can directly locate the switch that decide the interruption duration of loads, so we can use its switching time as the fault isolation time. The method can reflect effects of different types of terminal units on distribution system reliability. Besides, the method processes controllable three remote units using shortest path algorithm in graph theory. The RBTS BUS 2 test system is used to prove the validity of the proposed method. The proposed method is intuitively clear, has low computational complexity and can meet the requirements of real engineering.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司