李晓明,赵 鹏,邓笑冬,田 震,黄建明.多用户非均匀供电线路电压质量与线损优化方法研究[J].电测与仪表,2015,52(24):.
LI Xiao-ming,ZHAO Peng,DENG Xiao-dong,TIAN Zhen,HUANG Jian-ming.Study on Method to Optimizing the Voltage Quality and Line Losses of Multiple-user and Non-uniform Power Line[J].Electrical Measurement & Instrumentation,2015,52(24):.
多用户非均匀供电线路电压质量与线损优化方法研究
Study on Method to Optimizing the Voltage Quality and Line Losses of Multiple-user and Non-uniform Power Line
DOI:
中文关键词:  多用户  优化方法  动态无功补偿  电压质量  线损
英文关键词:multiple-user, optimal technology, dynamic reactive power compensation, voltage quality, line loss
基金项目:湖北省重点新产品新工艺研究开发项目(2012BAA2005);国家自然科学基金资助项目(51277134);江苏省基础研究计划(自然科学基金)资助项目(BK2011347)。
              
作者中文名作者英文名单位
李晓明LI Xiao-ming武汉大学电气工程学院
赵 鹏ZHAO Peng武汉大学电气工程学院
邓笑冬DENG Xiao-dong武汉大学电气工程学院
田 震TIAN Zhen上海交通大学电子信息与电气工程学院
黄建明HUANG Jian-ming武汉大学电气工程学院
摘要点击次数: 2489
中文摘要:
      本文从提高电压合格率和降低线损的角度出发,在研究具有用户数量多、负荷率低、容量小、线路线径不均特点的多用户非均匀供电线路的运行现状的基础上,提出多用户非均匀供电线路电压质量与线损优化方法:在额定容量高于某一特定容量的变压器的低压侧采用零过渡过程低压动态无功补偿技术,通过北斗主导多模系统同步授时协调控制;利用灵敏度分析方法和分区补偿原则,在高压侧灵敏度高的节点采取静态补偿技术,并采用前推回代法计算潮流分析电压质量与线损优化设计方法的实施效果。算例分析表明,本文所提的优化设计方法可以有效提高多用户非均匀供电线路的电压质量,降低其线路总有功功率损耗。
英文摘要:
      The aim of this paper is to increase the power factor and reduce the loss of power grid. After studying the multiple-user and non-uniform power line intimately, we get its features like having a large number of users but small in the capacity and load density, and the radius of transmission line different from each other. On the basis of that study, we propose an optimized technology to improve the voltage eligibility rate and reduce active power lose of multiple-user and non-uniform power line. The technology is about to use low-voltage reactive power dynamic compensation technology with zero transition in the low-pressure side of the transformer, whose rated capacity is larger than a specific one, and use the timing services of BeiDou Navigation Satellite System to coordinate the control process. In the high pressure side, take use of sensitivity analysis techniques and follow the principles of zonal compensation to compensate in the high sensitivity with the static compensation technology. The forward-backward sweep method is adopted in the power flow calculation and the analysis of the improvement of the proposed technology. The example shows that the proposed control technique can effectively improve the quality of the voltage along the multiple-user and non-uniform power line and reduce its total active power losse.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司