• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
刘海涛,张铭路,张亮,汪长林.基于双闭环电压控制静止同步补偿器在双馈风电场并网中参数设置及运行特性分析[J].电测与仪表,2015,52(17):.
Liu Haitao,Zhang Minglu,Zhang Liang,Wang Changlin.Analysis of Parameter Setting and Operation Characteristics on DFIG-based Wind Farm Integration with STATCOM Based on Dual-loop Voltage Control[J].Electrical Measurement & Instrumentation,2015,52(17):.
基于双闭环电压控制静止同步补偿器在双馈风电场并网中参数设置及运行特性分析
Analysis of Parameter Setting and Operation Characteristics on DFIG-based Wind Farm Integration with STATCOM Based on Dual-loop Voltage Control
DOI:
中文关键词:  静止同步补偿器  双馈风电场  电压控制  参数设置
英文关键词:STATCOM  DFIG-based wind farm  voltage control  parameter setting
基金项目:国家自然科学(51347010)
           
作者中文名作者英文名单位
刘海涛Liu Haitao南京工程学院电力工程学院
张铭路Zhang Minglu南京工程学院电力工程学院
张亮Zhang Liang南京工程学院电力工程学院
汪长林Wang Changlin梯级水电站运行与控制湖北省重点实验室(三峡大学)
摘要点击次数: 1946
中文摘要:
      静止同步补偿器(STATCOM)在柔性功率潮流控制及双馈风电场并网运行中得到广泛分析与讨论,而其双闭环电压控制策略的分析直接影响风电场并网运行特性。建立了基于电压源变流器(VSC)的静止同步补偿器通过耦合变压器与电网相连的电路模型,推导了双闭环电压控制环节的数学模型,分析了控制环节参数设置对于并网运行特性的影响。以标准三机九节点系统作为等效测试电网建立了双馈风电场并网模型,实例中以控制环节参数设置验证了衰减系数与电压设定值与无功控制的对应关系,以负荷投切小扰动为例分析了投入装置可以改善系统受扰动时的电能质量,并且通过不同类型的故障仿真验证了即使电力系统发生了最严重的三相短路故障,STATCOM也能快速补偿无功功率,有效提高系统的暂态稳定性。
英文摘要:
      STATCOM has been widely analyzed and discussed in flexible power flow control and operation of DFIG-based wind farm integration. Analysis on its dual-loop voltage control strategy directly affects the operation characteristics of wind farm integration. First, a circuit model of STATCOM based on VSC, which is connected to power grid through coupling transformer, is built. Then, the mathematical model of dual-loop voltage control link is derived and the impact of parameter in control link on integration operation characteristics is analyzed. Finally, a model of DFIG-based wind farm integration is established, which is using the three-machine nine-bus system as the equivalent power grid. Simulation results show that the corresponding relationship between the droop coefficient and reactive power and the power quality can be improved by using STATCOM. And through different types of fault simulation, it shows that the STATCOM can compensate reactive power quickly and improve transient stability of power system effectively even if there is the most serious three-phase short circuit fault.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司