• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
代志强,王维庆,何山,樊小朝,谢永流,高龙.双馈风力发电系统并网逆变器不同控制策略分析[J].电测与仪表,2016,53(7):.
DAI Zhiqiang,WANG Weiqing,HE Shan,FAN Xiaochao,XIE Yongliu,GAO Long.Comparative Analysis of Inverter Different Control for Double-fed Wind Power Generation System[J].Electrical Measurement & Instrumentation,2016,53(7):.
双馈风力发电系统并网逆变器不同控制策略分析
Comparative Analysis of Inverter Different Control for Double-fed Wind Power Generation System
DOI:
中文关键词:  双馈风力发电  并网逆变器  电网谐波  多谐振PR控制  电能质量
英文关键词:double-fed wind power generation  and inverter  harmonic  multi-resonant PR control  power quality
基金项目:国家自然科学基金:51267017,博士点专项基金:20136501120003
                 
作者中文名作者英文名单位
代志强DAI Zhiqiang新疆大学 电气工程学院
王维庆WANG Weiqing新疆大学 电气工程学院
何山HE Shan新疆大学 电气工程学院
樊小朝FAN Xiaochao新疆大学 电气工程学院
谢永流XIE Yongliu新疆大学 电气工程学院
高龙GAO Long国网宜宾电力公司
摘要点击次数: 2501
中文摘要:
      双馈风力发电系统并网逆变器采用并网电流反馈PI控制,虽然在理想电网条件下能够实现逆变器控制系统高功率因数、低稳态误差的性能,但存在电网谐波干扰情况时,系统的动稳态跟踪性能变差;此外,PI控制器可以直流信号实现零稳态误差,但无法消除交流信号的谐波分量,且需要多次的复杂坐标变换和解耦控制。由此,本文提出一种基于并网电流反馈、电容电流反馈的多谐振PR控制,提高了系统控制精度;引入低次谐波补偿项后,能够有效抑制并网电流波形畸变。仿真结果证明了本文提出的控制策略不仅能实现对交流信号无静差控制和具有良好的动稳态跟踪性能,而且系统并网电流的谐波含量较少,满足电网对风力发电系统并网的要求。
英文摘要:
      The double-fed wind power generation system and network grid inverter with current feedback PI control, although under ideal conditions can be achieved grid inverter control system, high power factor, low steady-state error performance, but there are harmonic interference when the situation, steady state and dynamic tracking performance deteriorates; in addition, PI controller can achieve zero steady-state error to DC signal, but do not eliminate the harmonic components of the AC signal, and the need for complex coordinate transformation and decoupling control several times. Thus, this paper proposes a grid-current feedback of multi-resonant PR capacitor current feedback control,and improve the control precision; the introduction of low-order harmonics compensation item, can effectively inhibit the grid current waveform distortion. Simulation results show that the proposed control strategy can not only realize the AC signal no static error control and has good dynamic and steady-state tracking performance, but also the system and less net current harmonic content, to meet the power and wind power system network claim.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司