王 超,李兴源,冯 明,黄 睿,李 妮,洪 潮.抑制多馈入直流输电系统相继换相失败的协调恢复控制策略[J].电测与仪表,2016,53(13):.
WANG Chao,LI Xingyuan,FENG Ming,HUANG Rui,LI Ni,HONG Chao.Coordinated recovery strategy for inhibiting continuous commutation failures in multi-infeed HVDC system[J].Electrical Measurement & Instrumentation,2016,53(13):.
抑制多馈入直流输电系统相继换相失败的协调恢复控制策略
Coordinated recovery strategy for inhibiting continuous commutation failures in multi-infeed HVDC system
DOI:
中文关键词:  多馈入直流输电系统  换相失败  短路比  多回协调恢复
英文关键词:multi-infeed  DC system, commutation  failure, short  circuit ratio, multi-circuit  coordinated recovery
基金项目:国家自然科学基金重点项目(51037003);南方电网公司科技项目(K-KY2013-001)
                 
作者中文名作者英文名单位
王 超WANG Chao四川大学 电气信息学院
李兴源LI Xingyuan四川大学 电气信息学院
冯 明FENG Ming四川大学 电气信息学院
黄 睿HUANG Rui四川大学 电气信息学院
李 妮LI Ni四川大学 电气信息学院
洪 潮HONG Chao中国南方电网有限责任公司 电网技术研究中心
摘要点击次数: 2240
中文摘要:
      针对多馈入直流系统容易出现的相继换相失败的问题,提出一种渐进恢复控制策略。为了确定各直流系统的恢复顺序,提出多馈入无功运行有效短路比(QMOESCR)指标,用来衡量直流系统受端电网强度和直流系统之间耦合程度的大小,并以此作为协调安排各直流系统故障后功率恢复速率的依据。然后,从改善交直流互联系统故障恢复特性的角度出发,对多回直流系统进行有序恢复,降低多回直流系统恢复过程中的无功需求,从而避免多回直流系统出现的相继换相失败,保证系统的安全稳定运行。分别对简单三馈入直流系统的电磁暂态仿真和南方电网机电暂态仿真的结果表明所提出的渐进协调恢复策略是有效的、可行的。
英文摘要:
      A progressive and coordinated recovery control strategy is proposed for continuous commutation failures in multi-infeed HVDC system. The index of Multi-Infeed Operating Effective Short Circuit Ratio considering reactive power which represent the strength of receiving AC system and the extent of coupling between different DC systems, is used as a criterion to determine the order of different DC systems. From the perspective of improving the recovery ability of AC/DC interconnected system, the sequential recovery strategy is employed for multi-circuit DC system to decrease the reactive requirement during the recovery process, so that the continuous commutation failure of multi-circuit DC system can be avoided and the system can operate safely and stably. The proposed recovery control strategy is implemented on a simple three-infeed DC system with electromagnetic transient simulation and China Southern Power Grid with electromechanical transient simulation, experiment results demonstrate the proposed approach is effective and feasible.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司