• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
李莲,林松霖.基于d-q坐标系的有源电力滤波器双闭环控制策略的研究(先确认排版稿正确)[J].电测与仪表,2016,53(16):.
Li Lian,Lin Songlin.The Research of Double Closed-loop Control Strategy for Active Power Filter Based on d – q Coordinates[J].Electrical Measurement & Instrumentation,2016,53(16):.
基于d-q坐标系的有源电力滤波器双闭环控制策略的研究(先确认排版稿正确)
The Research of Double Closed-loop Control Strategy for Active Power Filter Based on d – q Coordinates
DOI:
中文关键词:  有源电力滤波器  双闭环解耦  参数自调节模糊PI控制  重复控制  模糊-PI双模控制
英文关键词:Active  power filter, double  closed-loop  decoupling, Parameter  self-adjusting  fuzzy PI  control, repetitive  control, Fuzzy - PI  dual-mode  control
基金项目:
     
作者中文名作者英文名单位
李莲Li Lian天津理工大学,天津市复杂系统控制理论及应用重点实验室
林松霖Lin Songlin天津理工大学
摘要点击次数: 2445
中文摘要:
      一般对于普通工业负荷来说,要求有源电力滤波器需要滤除50次以内的谐波电流,传统的PI控制只能对直流分量进行无差控制,而且其带宽也不够。为了解决这个问题,文章对在d-q同步旋转坐标下前馈解耦的电流环控制器进行改进,引入重复控制与参数自调节模糊PI控制并联的复合控制策略,对重复控制回路参数进行了优化设计。对于传统的电压外环PI控制策略,因其参数整定复杂,且当系统负荷剧烈变化时无法保持稳定而产生大量纹波,鲁棒性差,对此文章采用模糊-PI双模控制策略。对于上述控制策略,在计算机上搭建其仿真模型,结果表明复合控制策略较PI控制策略具有更快的动态响应速度和更高的谐波补偿精度,而直流侧引入模糊-PI双模控制策略较之传统PI控制鲁棒性好,且响应迅速。
英文摘要:
      In general, the active power filter is required to filter harmonic current within 50 times for ordinary industrial load. The traditional PI control can only be carried out on the dc componentSwithout difference; what’s more, the bandwidth is not enough. In order to solve this problem, the current loop controller which is feed forward decoupled in d - q synchronous rotating coordinates is improved by this article, and the hybrid control strategy which is composed of theSparallel connection of repetitive control and parameter self-adjusting fuzzy PI control is proposed, the parameters of repetitive control loop are optimized. For the traditional PI control strategy of voltage loop, because the setting of the PI parameters is rather complex, when the load of the system experiencesSacute fluctuation, it will be unable to maintain stability and then generate a lot of ripple, the robustness of the system will be worse, so this article will use the Fuzzy - PI dual-mode control strategy. For the control strategy above, the simulation model is set up on computer, the results show thatScompared to the traditional PI control strategy, the introduction ofScomposite control strategy has faster dynamic response speed and higher precision of harmonic compensation, and compared to the traditional PI control strategy in the dc side, the introduction of the Fuzzy - PI dual-mode control strategy hasSgood robustness and fast response.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司