张安龙,翟学,李艳,林涛,吴俊鹏,陈汝斯.含光伏电源的配电网故障定位策略研究[J].电测与仪表,2015,52(16):.
ZHANG Anlong,ZHAI Xue,LI Yan,LIN Tao,WU Junpeng,CHEN Rusi.Research on Fault Location Method of Distribution Network With PV[J].Electrical Measurement & Instrumentation,2015,52(16):.
含光伏电源的配电网故障定位策略研究
Research on Fault Location Method of Distribution Network With PV
DOI:
中文关键词:  智能配电网  光伏电源  短路电流特性  最优母线  故障定位
英文关键词:smart distribution network  PV  fault current characteristics  the optimal bus  fault location
基金项目:
                 
作者中文名作者英文名单位
张安龙ZHANG Anlong深圳供电局有限公司
翟学ZHAI Xue武汉大学电气工程学院
李艳LI Yan深圳供电局有限公司
林涛LIN Tao武汉大学电气工程学院
吴俊鹏WU Junpeng武汉大学电气工程学院
陈汝斯CHEN Rusi武汉大学电气工程学院
摘要点击次数: 2191
中文摘要:
      基于监测电压暂降的配电网故障定位逐渐成为研究热点,同时随着智能配电网的发展,光伏电源越来越多的接入配电网。光伏电源的接入使传统的辐射型配电网的网络结构发生变化,且光伏电源的故障电流特性与同步发电机不同,使得基于电压暂降的配电网故障定位方法运用于含光伏电源的配电网时会产生较大误差。为了解决含光伏电源配电网的故障定位问题,基于低电压穿越控制策略针对光伏电源的短路电流特性进行了分析,然后介绍了含光伏电源的配电网故障电流的求解算法。通过遍历搜索候选母线,确定使得电气故障后故障电压实测值与理论计算值最为吻合的母线和故障类型,从而确定故障最邻近的母线。基于对IEEE34节点配电系统改造后的算例进行计算仿真,验证了本文方法应用于含光伏电源配电网定位的正确性和有效性。
英文摘要:
      Fault location of distribution network based on monitoring of voltage sag has become a hot research topic. With the development of smart grid, photovoltaic power (PV) is gaining more and more applications. The structure of distribution network with PV is different from the traditional radial distribution systems. Meanwhile, there is a great deal of variation in the fault current of PV and synchronous generator. Therefore, fault location based on monitoring of voltage sag will bring large error when applied in distribution network with PV. In order to solve the problem of fault location for distribution systems with PV, fault current characteristics of PV is studied with a control strategy for low voltage ride through (LVRT), then the calculation method of fault voltage of distribution network with PV is put forward. The theory of fault locating proposed is to search the assumed fault bus which makes the fault voltage measured is in agreement with the calculation value. Then the bus which is closest to fault position is obtained. Finally, a case study based on IEEE-34 node system is conducted to prove the correctness and effectiveness of the proposed method.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司