• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
朱子坤,黄龙,叶睆,曾建鑫,杨毅,曾祥君.一种无需参数整定的混合线路故障行波定位方法[J].电测与仪表,2016,53(19):.
Zhu Zikun,Huang Long,Ye Huan,Zeng Jianxin,Yang Yi,Zeng Xiangjun.A Novel Traveling Wave Based Fault Location Method with Non-parameter-threshold-setting for Hybrid Power lines[J].Electrical Measurement & Instrumentation,2016,53(19):.
一种无需参数整定的混合线路故障行波定位方法
A Novel Traveling Wave Based Fault Location Method with Non-parameter-threshold-setting for Hybrid Power lines
DOI:
中文关键词:  混合线路  参数整定  行波波速  故障定位
英文关键词:hybrid power lines, parameters setting, traveling wave velocity, fault location
基金项目:国家自然科学基金(61233008)、(51277014)和(51207014); 湖南省科技重大专项(2012FJ1003); 广东电网有限责任公司科技项目(K-GD2014-1017)
                 
作者中文名作者英文名单位
朱子坤Zhu Zikun广东电网有限责任公司茂名供电局
黄龙Huang Long长沙理工大学智能电网运行与控制湖南省重点实验室
叶睆Ye Huan广东电网有限责任公司茂名供电局
曾建鑫Zeng Jianxin广东电网有限责任公司茂名供电局
杨毅Yang Yi长沙理工大学智能电网运行与控制湖南省重点实验室
曾祥君Zeng Xiangjun长沙理工大学智能电网运行与控制湖南省重点实验室
摘要点击次数: 2219
中文摘要:
      为解决混合线路故障行波定位中行波波速与线路长度参数整定的难题,论文分析了行波在混合线路中传输特性,提出了一种无需参数整定故障行波定位方法。该方法在线路不同位置设置多个模拟故障点,依次试验测试或仿真测试线路首端到末端的各模拟故障点产生的故障行波传输到线路首端与末端的时间差,构建基准行波时差数组;当线路实际发生故障时,由行波采集装置测量行波信号到达线路首端与线路末端的时间差,与基准行波时差数组中各元素比较,判别故障区段;并计算故障点在故障区段线路的相对位置,根据各杆塔或电缆接头的位置确定故障点准确位置。仿真结果表明该方法无需整定线路长度和行波波速,且定位结果不受线路弧垂的影响,具有算法简单、实用性强、定位精度高的优点。
英文摘要:
      To solve the parameters threshold setting problem of travelling wave velocity and line length for traveling wave based hybrid power lines fault location, the transmission characteristics of traveling wave were analyzed, and a novel traveling wave based fault location method with non-parameter-threshold-setting was presented in this paper. First, the standard array of traveling wave arrival time difference between the two terminal of line was built with more faults simulated in the different positions of the line. Second, when the actual fault happened, the arrival time difference was measured and compared with each element of the standard array to detect the fault section. Finally, the fault point relative position in the fault section was calculated, and the fault point accurate position was also determined with the position of each tower or cable joint. The simulation results showed that the effectiveness and feasibility of the presented method with non-parameter-threshold-setting for hybrid power lines, and is with the simple algorithm, strong practicality and high accuracy for fault location.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司