• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
邹航,何威,陈瑜,刘斌,赵俊红,张欢欢.宽带电力线载波点对点通信性能测试平台设计[J].电测与仪表,2016,53(21):.
ZOU Hang,HE Wei,CHEN Yu,LIU Bin,ZHAO Jun-hong,ZHANG Huan-huan.Design of Point to Point Communication Performance Testing Platform for Broadband Power Line Carrier[J].Electrical Measurement & Instrumentation,2016,53(21):.
宽带电力线载波点对点通信性能测试平台设计
Design of Point to Point Communication Performance Testing Platform for Broadband Power Line Carrier
DOI:
中文关键词:  宽带  电力线载波  点对点通信  测试平台  级联滤波
英文关键词:broadband, power  line carrier, point  to point communication, testing  platform, cascade  filter
基金项目:中国南方电网有限责任公司科技项目(KJKM2014098)
                 
作者中文名作者英文名单位
邹航ZOU Hang云南电网有限责任公司昆明供电局
何威HE Wei珠海慧信微电子有限公司
陈瑜CHEN Yu云南电网有限责任公司昆明供电局
刘斌LIU Bin云南电网有限责任公司昆明供电局
赵俊红ZHAO Jun-hong云南电网有限责任公司昆明供电局
张欢欢ZHANG Huan-huan珠海慧信微电子有限公司
摘要点击次数: 2280
中文摘要:
      在Q/GDW 1379.4-2013通信单元检验技术规范的要求下,为测试低压宽带电力线载波通信单元的工作频段、载波信号发射功率谱密度、抗衰减能力、抗噪声干扰和抗阻抗变化等基本通信性能,给电网公司建设宽带电力载波远程集抄系统提供数据参考和方案依据。根据宽带电力线载波技术的特点搭建了点对点通信性能测试平台。该平台采用三级级联双SMA电源滤波组合,可有效隔离电网谐波、脉冲信号及电力线背景噪声对宽带载波通信单元性能的影响,使测试平台能够充分模拟低压电力线通道,还原现场集抄台区的运行状况,评估载波通信单元的实际可用性。试验数据证明:所建点对点通信性能测试平台试验环境纯净,对2~30MHz通带内的信号衰减达93dB,可确保宽带载波通信产品测试结果的稳定可靠。
英文摘要:
      In order to test the performances of working frequency, signal power spectral density,anti-jamming capability,noise immunity and anti-impedance changes for low voltage broadband power line carrier communication unit under the requirements of Q/GDW 1379.4-2013 technical specification and give data reference,scheme basis to grid company to construct remote metering system for broadband power line carrier.A point to point communication performance testing platform is formed according to the characteristics of broadband power-line carrier.Three cascade power filter with double SMA terminals are adopted which can insulate the influence on the communication performance for broadband carrier communication unit caused by harmonic,pulse signal and power-line background noise.As a consequence,the testing platform mentioned above can fully simulate the low voltage power line channel,restitute the operational state of site metering pilot and assess the actual usage of carrier communication unit.Experimental data certifies that the experiment environment of the testing platform constructed is pure,which can attenuate signal within the bandwidth of 1~30MHz up to 93dB so as to ensure that the tested performance data of broadband carrier communication unit is stable and reliable.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司