张兴隆,毛欣,曾灿,周旋,肖旭,何珉,周凯.基于冲击电压下有功损耗测量的电缆绝缘状态评估[J].电测与仪表,2016,53(23):.
Zhang Xinglong,Mao Xin,Zeng Can,Zhou Xuan,Xiao Xu,He Min,Zhou Kai.Assessment of Cable Insulation Condition Based on Active Power Loss Measurement under Impulse Voltage[J].Electrical Measurement & Instrumentation,2016,53(23):.
基于冲击电压下有功损耗测量的电缆绝缘状态评估
Assessment of Cable Insulation Condition Based on Active Power Loss Measurement under Impulse Voltage
DOI:
中文关键词:  冲击电压  冲击电流  有功损耗  分压器  罗氏线圈  LabVIEW
英文关键词:Impulse  voltage, Surge  current, Active  power loss, Divider, Rogowski  coil, LabVIEW
基金项目:
                    
作者中文名作者英文名单位
张兴隆Zhang Xinglong国网重庆市电力公司永川供电分公司
毛欣Mao Xin国网重庆市电力公司永川供电分公司
曾灿Zeng Can国网重庆市电力公司永川供电分公司
周旋Zhou Xuan国网重庆市电力公司永川供电分公司
肖旭Xiao Xu国网重庆市电力公司永川供电分公司
何珉He Min四川大学 电气信息学院
周凯Zhou Kai四川大学 电气信息学院
摘要点击次数: 1870
中文摘要:
      为评估运行电缆的绝缘状态,设计了一套基于LabVIEW的冲击电压及冲击电流的测量系统,在此基础上,提出了有功损耗评估电缆绝缘状态的方法。本测量系统采用两级分压的低阻尼阻容串联分压器作为电压传感器,空心罗氏线圈作为电流传感器,DS6104示波器作为数据采集装置,通过LabVIEW软件平台实现对示波器的控制及数据的采集和存储。测量结果表明该系统能够实现对冲击电压和冲击电流的自动同步采集和存储,波形无振荡、无畸变。通过测量水树老化电缆的冲击电压和冲击电流数据并进行数值积分,得到冲击下的有功损耗。与介质损耗正切值测量结果对比,发现两种评估手段的结论是一致的,表明有功损耗能够良好地反映电缆的绝缘状态。
英文摘要:
      To assess the cable insulation condition, a measurement system is presented to acquire the data of the impulse voltage and surge current based on LabVIEW, and a method of active power loss is proposed for the evaluation of insulation condition of the cable. A low damping resistance-capacitance series voltage divider based on two-stage division is designed as the voltage sensor, and a hollow Rogowski coil is designed as the current sensor. The DS6104 oscilloscope is designed as a data acquisition device, and the LabVIEW software platform is used to control the oscilloscope and acquire and store data. The measurement system can automatically and synchronously acquire and store the data of the impulse voltage and surge current without oscillation and distortion. The data of impulse voltage and surge current is measured, and numerical integration is calculated to obtain active power loss of the water tree aging cable. The active power loss and the dielectric loss are consistent for the same cables sample. It indicates that the active power loss can assess the cable insulation condition.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司