孔祥平,张哲,袁宇波,王业.低电压穿越控制策略下双馈风电机组故障电流特性的研究[J].电测与仪表,2016,53(20):.
Kong Xiangping,Zhang Zhe,Yuan Yubo,Wang Ye.The Study on the Fault Current Characteristics of Doubly Fed Induction Generator with Low-Voltage Ride-Through Control Strategy[J].Electrical Measurement & Instrumentation,2016,53(20):.
低电压穿越控制策略下双馈风电机组故障电流特性的研究
The Study on the Fault Current Characteristics of Doubly Fed Induction Generator with Low-Voltage Ride-Through Control Strategy
DOI:
中文关键词:  双馈风电机组  非严重故障  低电压穿越控制策略  故障电流特性
英文关键词:doubly-fed induction generator (DFIG), non-severe fault, low-voltage ride-through, control strategy, fault current characteristics
基金项目:
           
作者中文名作者英文名单位
孔祥平Kong Xiangping江苏省电力公司电力科学研究院
张哲Zhang Zhe强电磁工程与新技术国家重点实验室(华中科技大学)
袁宇波Yuan Yubo江苏省电力公司电力科学研究院
王业Wang Ye江苏省电力公司电力科学研究院
摘要点击次数: 1435
中文摘要:
      在电压跌落程度不大的远区非严重故障情况下,低电压穿越控制策略的采用使得双馈风电机组的转子绕组仍由变频器进行励磁。因此,非严重故障情况下双馈风电机组的故障电流特性取决于低电压穿越控制策略下变频器的响应特性。针对此,本文分析了低电压穿越控制策略下转子侧变流器的故障响应特性,得到了转子绕组故障电流的统一计算模型。在此基础上,对非严重故障情况下双馈风电机组的定子绕组故障电流特性进行了研究,建立了定子绕组故障电流的统一解析表达式。数字仿真结果证明了理论分析的正确性。
英文摘要:
      Under condition of non-severe fault, the depth of voltage dip is not very large. With the application of low-voltage ride-through scheme based on improved control strategy, the rotor windings of doubly fed induction generator (DFIG) are still excited by the AC/DC/AC converter. Hence, the fault current characteristics of DFIG under condition of non-severe fault are decided by the response of the AC/DC/AC converter with low-voltage ride-through control strategy. Aimed at it, the dynamic response characteristics of rotor-side converter (RSC) with low-voltage ride-through control strategy are analyzed, and the generalized calculation model of the rotor fault current is obtained. Based on it, the stator fault current characteristics of DFIG in condition of non-severe fault are studied. Meanwhile, the unified analytical expressions of the stator fault current are established. Finally, simulation examples in PSCAD/EMTDC demonstrate the theoretical analysis results.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司