赵庆杰,周凯,吴科,何珉,侯振奇.牵引机车过分相时高频谐波分析及对电缆终端发热问题研究[J].电测与仪表,2017,54(6):.
zhaoqingjie,zhoukai,wuke,hemin,houzhenqi.The Analysis of High Frequency Harmonic and the Research of the Problem for Cable Termination during Passing Natural Section of Traction Locomotive[J].Electrical Measurement & Instrumentation,2017,54(6):.
牵引机车过分相时高频谐波分析及对电缆终端发热问题研究
The Analysis of High Frequency Harmonic and the Research of the Problem for Cable Termination during Passing Natural Section of Traction Locomotive
DOI:
中文关键词:  牵引机车  高频谐波  电缆终端  红外成像  热点温升
英文关键词:Traction locomotive  High frequency harmonic  Cable terminal  Infrared imaging  Hot-spot temperature rise  
基金项目:
              
作者中文名作者英文名单位
赵庆杰zhaoqingjie四川大学
周凯zhoukai四川大学
吴科wuke四川大学
何珉hemin四川大学
侯振奇houzhenqi四川大学
摘要点击次数: 2349
中文摘要:
      摘要:针对牵引机车在过分相时产生高频谐波以及由此导致应力控制型电缆终端绝缘迅速裂化的问题,本文研究HXD1D型号的机车在过分相时网压、网流及电压波形畸变率的变化,及由此高频谐波对电缆终端的影响。实验通过搭建高频高压老化实验装置,利用高频高压发生装置对电缆终端施加不同的频率和电压,使用红外热成像分析高频谐波对电缆终端热点的影响。此外,通过电场仿真发现,在高频电压作用下,电缆终端外半导电层截断处的场强要明显大于工频电压下的场强。结果表明:机车在过分相时网压、网流波动比较明显,并由此带来的谐波比较严重,高频谐波含量比较丰富,在高频电压的作用下,应力控制型电缆终端的热点温升要明显高于工频电压下的温度变化。
英文摘要:
      ABSTRACT: In view of the traction engine produces high frequency harmonic in the excessive phase, which causes stress control type cable terminal insulation, broken rapidly, this paper studies HXD1D type of locomotive net, net flow in the excessive phase and the change of the voltage waveform distortion rate, and high frequency harmonic effect on the cable termination. Aging experiment through constructing high frequency high voltage experiment device, the use of high frequency high voltage generator of cable terminal exert different frequency and voltage, using infrared thermal imaging analysis of high frequency harmonic effects on cable terminal hot spots. In addition, by the electric field simulation. It found that under the effect of high-frequency voltage, the cable terminal outer semiconductive layer truncation of field strength is significantly greater than under power frequency voltage field. The results show that the locomotive net, net flow pressure fluctuation in the excessive phase are more noticeable, and the resulting harmonic serious, high frequency harmonic content are rich, under the action of high frequency voltage, stress control type hot spot temperature rises significantly higher than the end of the cable under power frequency voltage temperature.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司