李嘉恒,任惠,师璞,孙辰军,王飞.基于用户自定义特征的反时限有源配网保护方案[J].电测与仪表,2017,54(6):.
Li Jiaheng,Ren Hui,Shi Pu,Sun Chenjun,Wang Fei.User-defined characteristics Based Inverse Timing Protection Scheme for Active Distribution Network[J].Electrical Measurement & Instrumentation,2017,54(6):.
基于用户自定义特征的反时限有源配网保护方案
User-defined characteristics Based Inverse Timing Protection Scheme for Active Distribution Network
DOI:
中文关键词:  有源配电网  分布式电源  用户自定义特征  参数优化  反时限过流保护
英文关键词:active  distribution network, DG, User-defined  characteristics, parameter  optimization, inverse  time overcurrent  relays
基金项目:国家电网公司科技项目(SGTYHT/13-JS-175);河北省科技支撑计划重点项目(12213913D)
              
作者中文名作者英文名单位
李嘉恒Li Jiaheng新能源电力系统国家重点实验室(华北电力大学)
任惠Ren Hui新能源电力系统国家重点实验室(华北电力大学)
师璞Shi Pu国网河北供电公司保定供电分公司
孙辰军Sun Chenjun国网河北省电力公司
王飞Wang Fei新能源电力系统国家重点实验室华北电力大学;电力系统及发电设备控制和仿真国家重点实验室清华大学电机系
摘要点击次数: 2451
中文摘要:
      由于分布式电源输出功率的随机性与波动性,当分布式电源大量接入配电网后,传统的反时限过电流保护方案很难满足配电网保护选择性和速动性的要求。为此,本文通过研究数字反时限过流保护继电器,提出一种基于用户自定义特征的反时限过电流保护方案。保护方案将反时限继电器的特性常数(A)和反时限的类型常数(B)同继电器的时间整定系数、启动电流共同作为待优化的连续变量,并以最小故障电流时所有保护动作时间之和最小为目标函数,利用内点法求解保护的最优配置。方案保证了线路出口处故障时保护能快速动作,满足了配电网保护选择性和速动性的要求。最后,通过仿真分析,对保护方案进行了验证。
英文摘要:
      The access of distributed generations adds new sources to distribution network,which changes the grid structure.The traditional inverse-time overcurrent protection scheme is difficult to satisfy the requirements of selectivity and speed because of randomness of DG’s output power.The digital inverse time overcurrent relay were considered here and a new protection scheme of inverse-time overcurrent protection based on user-defined characteristics was proposed. The proposed protection scheme considers the two relay characteristics constants(A、B) and pick up current、time multiplier setting as continuous variable settings that can be adjusted. The main objective is to minimize the overall time of operation of relays considering the minimum fault current. Four parameters are optimized By using interior-point method to achieve the optimal configuration of the protection.It makes protective relays act instantaneously when fault occurs at line exit end and satisfies the requirements of selectivity and speed. Finally,verification of the protection scheme is carried out by simulation analysis.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司