程乐峰,殷林飞.基于变频信号注入原理的防带地线合闸检测装置设计[J].电测与仪表,2016,53(21):.
Cheng Lefeng,Yin Linfei.Development of detector for anti-closing with grounding wire based on variable frequency signal injection principle[J].Electrical Measurement & Instrumentation,2016,53(21):.
基于变频信号注入原理的防带地线合闸检测装置设计
Development of detector for anti-closing with grounding wire based on variable frequency signal injection principle
DOI:
中文关键词:  检修改造  接地线  带地线合闸  变频信号注入  DSP
英文关键词:maintenance and rebuilding, grounding wire, closing with grounding wire, variable signal injection, DSP
基金项目:中国南方电网科技项目资助(K-GD2014-204); 国家自然科学基金项目(51177051,51477055).
     
作者中文名作者英文名单位
程乐峰Cheng Lefeng华南理工大学电力学院
殷林飞Yin Linfei华南理工大学电力学院
摘要点击次数: 1691
中文摘要:
      针对10kV及以下电压等级配电网线路检修或改造过程中临时挂接地线检测问题,研究一种变频信号注入检测方法,并开发基于DSP2812的防带地线合闸检测装置,装置生成变频电压检测信号,并不断注入到检测回路中,回路由装置、线路、接地线和大地等构成,检测回路的三相电压、电流信号不断被采样,经调理后输入至CPU进行综合判断分析,从而对线路是否存在三相接地线、两相接地线、单相接地线和无接地线情况进行有效检测,并对线路相间短路情况进行识别。装置基于模块化设计,采用高速数据处理芯片,利用FFT算法分别求解基波和谐波成分,不仅可有效判断出有用信号,还可以判断线路中感应信号的强弱,现场试验表明其在技术上可有效避免“带地线合闸”这一恶性事故,有一定的参考价值。
英文摘要:
      Aimed at problems of temporary hanged grounding wire detection during lines maintenance or rebuilding work of distribution network in 10 kV and under the voltage grade, a detection method based on variable frequency injection principle was studied, and a detector for anti-closing with grounding wire was developed based on DSP2812, the variable voltage signal was produced and injected into the detection loop circuit, which was composed of detector, distribution line, grounding wire and the earth, etc. Three-phase voltage and current signals were sampled, and after conditioning, were transmitted into CPU for comprehensive analysis, which could detect the wires in three-phase, two-phase and single-phase grounding situations, as well as no grounding and inter-phase short connection situations. The detector was modular design with high speed data processing chip, and in which the FFT algorithm was used to resolve the fundamental wave and harmonic, can availably judge the useful signals, and the intensity of inductive signal exists in wires. It is proved from the field test that the vicious accident of “closing with grounding wire” can be avoided in usage of the designed detector and which has a certain reference value.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司