李永明,杨 骏,王洋洋,邹岸新,徐禄文.500kV超高压输电线下山坡周围工频电场分析[J].电测与仪表,2017,54(6):.
Li yongmin,YangJun,Wang yangyang,zou anxin,Xu luwen.Simulation analysis on the frequency electric field of slope under 500KV EHV power transmission lines[J].Electrical Measurement & Instrumentation,2017,54(6):.
500kV超高压输电线下山坡周围工频电场分析
Simulation analysis on the frequency electric field of slope under 500KV EHV power transmission lines
DOI:
中文关键词:  山坡  工频电场  模拟电荷法  影响因素
英文关键词:three-dimension  slope , power  frequency electric  field, charge  simulation method, influence  factor
基金项目:国家自然科学基金项目(面上项目,重点项目,重大项目)
              
作者中文名作者英文名单位
李永明Li yongmin输配电装备及系统安全与新技术国家重点实验室重庆大学
杨 骏YangJun输配电装备及系统安全与新技术国家重点实验室重庆大学
王洋洋Wang yangyang输配电装备及系统安全与新技术国家重点实验室重庆大学
邹岸新zou anxin国网重庆市电力公司电力科学试验研究院
徐禄文Xu luwen国网重庆市电力公司电力科学试验研究院
摘要点击次数: 1791
中文摘要:
      在输电线下电场的计算中,普遍将输电线下地面视为平地,而忽略了不规则地面对输电线下电场计算的影响。为此建立了山坡周围工频电场的计算模型,基于模拟电荷法分析了平地及山坡表面的电场分布,并分析了影响山坡周围电场分布的因素。研究表明,山坡对输电线下电场分布有明显影响,电场在靠近山坡坡脚处逐渐减小,在随着山坡高度的增加而逐渐上升,在坡顶处电场发生畸变。山坡的角度、高度、输电线与山坡的相对位置及输电线的剖分密度对其周围电场计算都会产生影响,角度越大,高度越高,在山坡顶部电场的畸变越明显。输电线与山坡之间的夹角越大,在坡脚处电场减弱的趋势越明显。
英文摘要:
      In the electric field calculation of transmission line mostly treat the ground which is under the lines as the ground so that ignore the influence of irregular ground to the electric field calculation; Thus, a three-dimension model to compute power frequency electric field surround the slope under the transmission line is built . According to charge simulation method, the distribution of power frequency electric field at ground and slope surface is analyzed, and the factors impacting computational results of electric field are discussed. Research results shows that there is a great impact on ground surface electric field nearby the slope. The effect is that close to slope toe, the power frequency electric field of EHV transmission is weakened and the field is strengthened with the height of the slope become higher, and the electric field distortion appears at the top of slope. Computation result of electric field will be impacted by the angle and altitude of the slope, the position of the transmission line between the slope, the density of the simulation charge of the transmission line .The larger angle, the higher height of the slope, the electric field distortion is become obviously. The angle of the slope and the power lines is more greater and the reducing of the electric field is moer abviously .
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司