刘翔宇,何玉灵,孟凡超,李晓明,李晓军,王晓蔚.既定PSS在不同运行状态下的适应性分析*[J].电测与仪表,2016,53(15):.
Liu Xiang Yu,He Yu-ling,Meng Fan-chao,Li Xiao-ming,Li Xiao-jun,Wang Xiao-wei.Adaptation Analysis on Fixed PSS under Different Performing Conditions[J].Electrical Measurement & Instrumentation,2016,53(15):.
既定PSS在不同运行状态下的适应性分析*
Adaptation Analysis on Fixed PSS under Different Performing Conditions
DOI:
中文关键词:  PSS,多运行方式,适应性,Prony分析,PSD-BPA
英文关键词:Power  system stabilizer (PSS), multi-operating  conditions, adaptability, Prony  analysis, PSD-BPA
基金项目:国家自然科学基金项目(面上项目,重点项目,重大项目)
                 
作者中文名作者英文名单位
刘翔宇Liu Xiang Yu国网河北省电力公司电力科学研究院
何玉灵He Yu-ling华北电力大学设备故障诊断与检测技术研究所
孟凡超Meng Fan-chao国网河北省电力公司电力科学研究院
李晓明Li Xiao-ming国网河北省电力公司电力科学研究院
李晓军Li Xiao-jun国网河北省电力公司电力科学研究院
王晓蔚Wang Xiao-wei国网河北省电力公司电力科学研究院
摘要点击次数: 1760
中文摘要:
      分析了不同运行状态下既定PSS的适应性。首先阐述了Prony算法的基本思想,并通案例验证了Prony方法在工程PSS分析中精度是可行的;然后通过PSD-BPA仿真计算分别分析了机组负荷系数、电网负荷、电网结构变化时机组的振荡特性变化规律和既定PSS的适应性,并给出了PSS参数整定的建议参考流程。分析表明,机组负荷系数和电网负荷增大均会使发电机主导振荡频率降低,但电网结构改变时,其主导振荡频率有可能升高也有可能降低,不具备明显规律;当机组负荷系数变大时,既定PSS适应性先变差再变好,而当电网负荷增大时,结论相反。论文成果对于PSS参数的整定改进有参考意义。
英文摘要:
      This paper investigates the adaptation of PSS under different running conditions. The principles of Prony are firstly studied, and the accuracy of this method for the engineering calculation is also confirmed by an example. Then based on the PSD-BPA simulation computing, the vibration characteristics of the generator set, and the adaptation of PSS with the variations of the generator load factor, the grid load and the grid structure, are respectively analyzed. The corresponding suggested flow chart of the PSS parameter setting is proposed as well. It is shown that, as the generator load factor or the grid load is increased, the vibration frequency will be decreased. However, there are no evident rules for the frequency change when the grid structure is changed. As the generator load factor rises, the adaptation characteristic will be firstly debased and then optimized, while the increment of the grid load will result in an opposite result. The achievements obtained in this paper can be used as a reference for the PSS parameter setting improvement.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司