张凯军,胡志坚,张博成.计及地线耦合的利用架空线路测量接地网接地阻抗的方法[J].电测与仪表,2017,54(12):.
zhangkaijun,huzhijian,zhangbocheng.Method for Measuring Grounding Resistance of Grounding Grid Considering the Influence of Earth Wire Coupling[J].Electrical Measurement & Instrumentation,2017,54(12):.
计及地线耦合的利用架空线路测量接地网接地阻抗的方法
Method for Measuring Grounding Resistance of Grounding Grid Considering the Influence of Earth Wire Coupling
DOI:
中文关键词:  接地阻抗  测量  接地网  架空地线  分流  互感干扰
英文关键词:grounding impedance  measurement  grounding grid  overhead line  shunt current  interference from coupling lines
基金项目:
        
作者中文名作者英文名单位
张凯军zhangkaijun武汉大学电气工程学院
胡志坚huzhijian武汉大学电气工程学院
张博成zhangbocheng武汉大学电气工程学院
摘要点击次数: 1602
中文摘要:
      在利用架空线路测量接地网接地阻抗时,未断开接地网与架空地线的连接构架会使通过接地网流入大地的电流小于实际注入电流,且经过地线的分流电流由于架空地线与相线间的电磁耦合效应会在线路中产生干扰电压。因此本文提出在测量接地网对地电压和实际注入电流时,同步测量地线电流以减小分流效应造成的误差;并通过多次测量的数据建立数学模型进行计算,以减小测量线路与地线的电磁耦合效应产生的感应电压对接地阻抗测量产生的影响。仿真结果表明,在电压极之前的杆塔与地线绝缘或者直接相连的杆塔数目较少的情况下,本文所提测量方法能有效减小用架空线路测量接地网接地阻抗时地线分流造成的接地阻抗测量误差。
英文摘要:
      When overhead lines are used to measure the impedance of grounding grid, the current through grounding grid is less than actual injected if the ground grid is connected with the overhead ground lines. The current bypass the ground line will generate a coupling voltage on the circuit because of the electromagnetic coupling effect between ground line and conduct line. In order to reduce the measurement error caused by ground line shunt, this paper proposed that ground line shunt should be measured at the same time when the voltage of ground grid and actual injected current are measured. And a mathematical model is built by a few measurement data to reduce the influence of the electromagnetic coupling effect between ground line and conduct line. The simulation results show that if there are few towers connected with the ground line, the proposed method can effectively reduce the measurement error caused by ground line shunt current when the overhead line is used to measure the grounding impedance.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司