王增平,赵兵,李泽坤,孙毅,李彬.(12期拿下)基于Apriori关联规则的电能表检定质量影响因素分析[J].电测与仪表,2017,54(13):.
Wang Zengping,Zhao Bing,Li Zekun,Sun Yi,Li Bin.Impact factor analysis based on Apriori association rules for electric energy meter’s verification quality[J].Electrical Measurement & Instrumentation,2017,54(13):.
(12期拿下)基于Apriori关联规则的电能表检定质量影响因素分析
Impact factor analysis based on Apriori association rules for electric energy meter’s verification quality
DOI:
中文关键词:  电能表  检定项目  数据挖掘  关联规则  质量影响因素
英文关键词:electric  energy meter, verification  items, data  mining, association  rule, quality  factors
基金项目:
              
作者中文名作者英文名单位
王增平Wang Zengping华北电力大学
赵兵Zhao Bing中国电力科学研究院
李泽坤Li Zekun华北电力大学
孙毅Sun Yi华北电力大学
李彬Li Bin华北电力大学
摘要点击次数: 1213
中文摘要:
      电能表的质量问题直接影响了用户侧的供电可靠性与安全性,关系到国家电网系统稳定与经济运行。针对目前电能表质量存在的不足,本文应用了Apriori关联规则数据挖掘方法,将7种检定试验结果作为质量评估指标,对这7类影响因素做了关联分析,得到了各个检定试验项目对检定质量的影响程度。同时探讨了检定项目的内部关联,找出了高频连带出现的不合格检定项目。在分析这些检定项高频出现的原因的基础上,得出了电能表质量薄弱点集中在计量模块这一结论。本文为提高检定通过率、提高产品质量提供了参考。
英文摘要:
      The quality of electric energy meters has a direct influence on power supply reliability and safety of the user side, which strongly related to the national grid system stability and economic operation. According to the current existing defects of electric energy meters, this paper considers seven verification test results as quality evaluation indexes and analyzes associations of these seven quality factors by Apriori association rules data mining methods. Therefore, the degree of influence caused by verification items on verification quality has been determined. This paper also discusses the inner association between seven verification items and has found some failed verification items of an associated high frequency. Considering the reasons for these high-frequent items, the conclusion that current weak points of electric energy meters are concentrated on metering modules has been founded. In all, this paper provides a reference for improving verification tests pass rate and ameliorating products.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司