李贺龙,王雪敏,赵进全,王卓,洪平,皮李刚.基于Fryze时域无功定义的无功电能的准确计量[J].电测与仪表,2017,54(1):.
Li Helong,Wang Xuemin,Zhao Jinquan,Wang Zhuo,Hong Ping,Pi Ligang.Accurate measurement of reactive power based on Fryze’s reactive power theory in time-domain[J].Electrical Measurement & Instrumentation,2017,54(1):.
基于Fryze时域无功定义的无功电能的准确计量
Accurate measurement of reactive power based on Fryze’s reactive power theory in time-domain
DOI:
中文关键词:  无功电能计量  非正弦不平衡  Fryze时域无功定义  正向无功功率  反向无功功率
英文关键词:reactive  power measurement, non-sinusoidal  and asymmetry, Fryze’s  reactive power  theory in  time domain, positive  reactive power, negative  reactive power
基金项目:
                 
作者中文名作者英文名单位
李贺龙Li Helong中国电力科学研究院
王雪敏Wang Xuemin西安交通大学 电气工程学院
赵进全Zhao Jinquan西安交通大学 电气工程学院
王卓Wang Zhuo西安交通大学 电气工程学院
洪平Hong Ping西安交通大学 电气工程学院
皮李刚Pi Ligang西安交通大学 电气工程学院
摘要点击次数: 2819
中文摘要:
      针对目前无功功率计量算法在非正弦不平衡条件下的无功功率计量方面准确性的不足,本文在Fryze时域无功定义的基础上提出了一种适用于非正弦不平衡三相三线制系统的无功功率计量理论。根据Fryze时域无功定义将三相瞬时电流分解为有功电流分量和无功电流分量,并对三相瞬时电压和无功电流分量进行快速傅里叶变换,得到各次谐波无功功率的大小和方向,从而实现对非正弦不平衡三相三线制系统无功电能的准确计量。该方法将无功功率分为正向无功功率和反向无功功率,避免了同一谐波源产生的不同次数谐波的感性无功与容性无功相互抵消的情况。最后通过Matlab仿真验证了这一结论,为非正弦不平衡条件下系统无功电能的准确计量提供了理论依据。
英文摘要:
      In allusion to the lack of accuracy of reactive power measurement methods at present under the condition of non-sinusoidal and asymmetry, this paper puts forward a reactive power measurement theory which is applicable to three-phase three-line system under the condition of non-sinusoidal and asymmetry based on Fryze’s reactive power theory in time-domain. According to Fryze’s reactive power theory in time-domain, three-phase instantaneous current can be decomposed into active current component and reactive current component. Then the value and direction of reactive power of each harmonic can be achieved by FFT analysis on three-phase instantaneous voltage and reactive current component so as to realize the accurate measurement of reactive power of three-phase three-line system under the condition of non-sinusoidal and asymmetry. In this method, the reactive power are divided into positive reactive power and negative reactive power to avoid the offset of inductive reactive power and capacitive reactive power under different harmonic frequency generated by the same harmonic source which is finally verified by Matlab simulation and provides theory basis for accurate measurement of reactive power under the condition of non-sinusoidal and asymmetry.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司