王伟,魏菊芳,王楠,王巨伟,王永强.有限元和有限体积法结合的油浸式变压器温度场计算方法[J].电测与仪表,2017,54(18):.
Wang Wei,Wei Jufang,Wang Nan,Wang Juwei,Wang Yongqiang.The Finite Element and Finite Volume Method Combined With 3D Temperature Field Calculation of Transformer[J].Electrical Measurement & Instrumentation,2017,54(18):.
有限元和有限体积法结合的油浸式变压器温度场计算方法
The Finite Element and Finite Volume Method Combined With 3D Temperature Field Calculation of Transformer
DOI:
中文关键词:  油浸式变压器  三维温度场,有限元法  有限体积法(FVM)  预条件共轭梯度法
英文关键词:oil immersed transformer  three- dimensional temperature field, the finite element method  finite volume method (FVM)  preconditioned conjugate gradient method
基金项目:
              
作者中文名作者英文名单位
王伟Wang Wei国网天津市电力公司电力科学研究院
魏菊芳Wei Jufang国网天津市电力公司电力科学研究院
王楠Wang Nan国网天津市电力公司电力科学研究院
王巨伟Wang Juwei华北电力大学河北省输变电设备安全防御重点实验室
王永强Wang Yongqiang华北电力大学河北省输变电设备安全防御重点实验室
摘要点击次数: 1948
中文摘要:
      油浸式电力变压器是电网中的重要设备,其故障往往是由内部绝缘老化引起的。实际运行中,如果可以准确计算出变压器的温度场和绕组热点温度,对延长其寿命和电网的稳定性有重要的意义[1]-[5]。为了准确算得油浸变压器的温度场,经过对比有限元和有限体积法的各自优点,提出了一种新的变压器温度场分布的混合计算方法;并以一台110KV / 31.5MVA变压器为例,建立立体模型,并利用有限元和有限体积混合方法,得到变压器的温度场分布结果。通过对比运行监测到的变压器顶层油温数据和混合方法得到的计算结果,结果表明,混合计算方法的计算结果与监测数据的平均误差只有1.6℃,证明了这种计算方法能更准确计算油浸式变压器的温度场。
英文摘要:
      Oil immersed transformer is an important equipment of power system, whose fault is often caused by the aging of insulation. In actual operation, accurate calculation of the temperature field of transformer winding hot spot temperature in particular, has a very important significance for stabilizing the operation of power grid and extending life of the transformer. In order to accurately calculate the temperature field of oil immersed transformers, a hybrid method which is based on comparison of respective advantages of the finite element method and finite volume method is proposed; it takes a transformer of 110KV / 31.5MVA as example, using mixed method of finite element method and finite volume method, the three-dimensional temperature field of transformer is calculated. By comparing the figures of top oil temperature of transformer monitored by the operating transformer and the figures calculated by mixed method, the margin error of the hot spot temperature is only 1.6 ℃, proves that this hybrid method can accurately calculate the internal temperature field of oil immersed transformer.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司