• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
胡浩亮,陆以彪,徐自立,李登云,熊前柱,肖霞.PEVT和AEVT在实验室和在线运行状态下误差特性比较研究[J].电测与仪表,2017,54(19):.
huhaoliang,luyibiao,xuzili,lidengyun,Xiong Qian-zhu,xiaoxia.Research on Error Characteristics of PEVT and AEVT in the Conditions of Laboratory and On-line Operation[J].Electrical Measurement & Instrumentation,2017,54(19):.
PEVT和AEVT在实验室和在线运行状态下误差特性比较研究
Research on Error Characteristics of PEVT and AEVT in the Conditions of Laboratory and On-line Operation
DOI:
中文关键词:  PEVT  AEVT  测试环境  在线运行  误差特性
英文关键词:PEVT  AEVT  test environment  on-line operation  error characteristics
基金项目:国家电网公司科技项目(JL71-15-040)
                 
作者中文名作者英文名单位
胡浩亮huhaoliang华中科技大学,中国电力科学研究院
陆以彪luyibiao黑龙江省电力有限公司电能计量中心
徐自立xuzili中国电力科学研究院
李登云lidengyun中国电力科学研究院
熊前柱Xiong Qian-zhu中国电力科学研究院
肖霞xiaoxia华中科技大学
摘要点击次数: 2086
中文摘要:
      PEVT和AEVT是目前在电网投运的两类典型EVT,但其投运前均需在现场对误差特性进行二次定标。为了研究EVT实验室和在线运行状态下的误差特性,选取业内两主流厂家的PEVT和AEVT试品,对其开展了实验室和在线运行为期一年多的误差特性比较研究。结果表明,测试环境对PEVT比差的影响低于0.05%,实验室温度特性在-40°C ~ 53.5°C温度范围内,比差变化最大达4.3%;现场运行时的温度特性在温度范围-20°C ~40°C之间,比差的变化为0.55%。AEVT对测试环境敏感,比差从实验室时0.03%、现场离线为0.18%,现场在线变为0.36%;但其温度特性较好,实验室温度特性在-40°C ~ 63°C的温度范围内,比差变化为0.21%,AEVT现场温度特性在温度范围-20°C ~40°C之间,比差的变化在0.1%以内。另外,EVT的温度特性对温度变化梯度敏感,现场实际运行时的温度特性优于实验室的温度特性。
英文摘要:
      PEVTs and AEVTs are currently two kinds of typical EVTs in operation in power grid, but they would be required to calibrate error characteristics again before the operation. In order to research error characteristics of EVTs in three state of laboratory and field off-line and on-line operation, PEVT and AEVT samples from two mainstream manufacturers were selected to carry out the comparative study of error characteristics. The results show that the effect of the testing environment on ratio error of PEVT is less than 0.05%; however, the variable quantity of ratio error in laboratory is 4.3% with the temperature in - 40℃~ 53.5℃ and 0.55% in on-line operation in the temperature range of - 20℃ ~ 40℃. The ratio error of AEVT is sensitive on the test environment with the error from laboratory 0.03%, off-line scene 0.18% and on-line operation 0.36%; but the variable quantity of ratio error in laboratory is 0.21% within the temperature range of - 40℃~ 63℃ and 0.1% in on-line operation within the temperature range of - 20℃ ~ 40℃. In addition, the temperature characteristics of EVTs were sensitive to temperature gradient, and the temperature characteristic in on-line operation is better than in laboratory.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司