郝金鹏,张鸿业,郭飞,郭俊,李秀广,吴旭涛.辐射电场特征能量提取法在评估GIS状态中的应用研究[J].电测与仪表,2018,55(3):123-128.
Hao Jinpeng,ZHANG Hongye,GUO Fei,GUO Jun,Li Xiuguang,Wu Xutao.Research on extraction of characteristic energy of radiated E-field method in evaluating GIS status[J].Electrical Measurement & Instrumentation,2018,55(3):123-128.
辐射电场特征能量提取法在评估GIS状态中的应用研究
Research on extraction of characteristic energy of radiated E-field method in evaluating GIS status
DOI:
中文关键词:  小波包分解  特征提取  辐射电场  GIS  CB  状态评估
英文关键词:wavelet packet decomposition  feature extraction  radiated E-field  GIS  CB  state assessment
基金项目:国家自然科学基金项目( 重点项目)
                 
作者中文名作者英文名单位
郝金鹏Hao Jinpeng国网宁夏电力公司电力科学研究院
张鸿业ZHANG Hongye西安交通大学电气工程学院
郭飞GUO Fei国网宁夏电力公司
郭俊GUO Jun西安交通大学电气工程学院
李秀广Li Xiuguang国网宁夏电力公司电力科学研究院
吴旭涛Wu Xutao国网宁夏电力公司电力科学研究院
摘要点击次数: 2043
中文摘要:
      气体绝缘变电站(gas insulated substation,GIS)内的隔离开关(disconnecting switch, DS) 或者断路器(circuit breaker,CB)的动作会在GIS外部产生强烈的辐射电磁场环境。为了通过此测得的辐射场特征参数评估GIS的健康状态,特提出利用小波包分解提取辐射电场信号特征频段能量的方法。采用bior5.5小波基函数,分别对GIS处于健康状态与GIS中CB内出现绝缘故障两种情况下CB关合动作所产生的辐射电场信号进行4层小波包分解,从而提取不同频段的归一化能量,发现31.25MHz以下的频段为此GIS因CB动作所产生辐射电场信号的特征频段。经推广,通过对比任意一次CB动作后辐射电场在特征频段的能量与GIS正常运行状态下典型辐射电场的特征频段的能量,可以诊断CB的绝缘故障,评估GIS的健康状态。
英文摘要:
      Switching operations of a disconnecting switch (DS) or a circuit breaker (CB) in a gas insulated substation (GIS) can stimulate outside GIS strong radiated electromagnetic fields. In order to assess the status of GIS through its characteristic parameters, a method of extracting the characteristic frequency-band energy of the electric field (E-field) based on wavelet packet analysis is proposed. Using the bior5.5 wavelet basis function, the radiated E-field signals of CB in good condition and those of CB in which insulation fault happens are separately decomposed into 4 layers, and the normalized energies of different frequency bands are extracted; then it’s found that the frequency band below 31.25MHz is the characteristic band of radiated E-field. By comparing the energies in the characteristic frequency bands after a random CB operation with that of the typical radiated E-field obtained when GIS totally is in good condition, insulation faults of CB can be detected and the operating state of GIS could be assessed.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司