葛梦昕,傅裕斌,樊友平,孙晓瑜,邹显斌,陈子涵.采用异步联网限制短路电流的实际应用和分析[J].电测与仪表,2018,55(4):40-47.
GE Mengxin,FU Yubin,FAN Youping,SUN Xiaoyu,ZOU Xianbin,CHEN Zihan.Practical application and analysis of short-circuit current limiting by asynchronous grid interconnection[J].Electrical Measurement & Instrumentation,2018,55(4):40-47.
采用异步联网限制短路电流的实际应用和分析
Practical application and analysis of short-circuit current limiting by asynchronous grid interconnection
DOI:
中文关键词:  短路电流  直流背靠背  限流措施  限流效果  可靠性
英文关键词:Short circuit current limitation  Back to back DC transmission  Current limiting effect  Current limiting measures  Reliability
基金项目:
                 
作者中文名作者英文名单位
葛梦昕GE Mengxin武汉大学 电气工程学院
傅裕斌FU Yubin武汉大学 电气工程学院
樊友平FAN Youping武汉大学 电气工程学院
孙晓瑜SUN Xiaoyu武汉大学 电气工程学院
邹显斌ZOU Xianbin武汉大学 电气工程学院
陈子涵CHEN Zihan武汉大学 电气工程学院
摘要点击次数: 2133
中文摘要:
      500kV主网短路电流超标问题已成为广东电网运行近年来最突出的问题之一。现有的运行措施可将超标站点短路电流暂时降低至安全水平,但电网整体的短路电流水平仍较高,且牺牲了部分系统安全可靠性,从长远来看通过直流背靠背异步互联限制短路电流是可行的解决办法。以2018年广东500kV电网为研究对象,建立直流背靠背异步互联模型,从短路电流限制效果、系统可靠性等方面对进行仿真计算,并与传统运行措施进行对比,可以得出,采用直流背靠背异步互联措施具有更好的限流效果和更高的安全可靠性,验证了该方案在短路电流限制方面的有效性和优越性。
英文摘要:
      The main problem of 500kV short-circuit current overweight has become one of the most prominent issues of Guangdong power grid in recent years. The existing operation measures can reduce excessive short-circuit current to safe levels temporarily, but the short circuit current level of the whole power grid is still high, with sacrificing the part safety and reliability of the system. In the long run, limiting short-circuit current through the back-to-back HVDC asynchronous interconnection is a feasible solution. Guangdong 500kV power grid in 2018 as the research object, the model of back-to-back HVDC asynchronous interconnection is established. And with the simulation of the short circuit current limiting effect and the system reliability, compared with traditional operation measures, we can obtain that back-to-back HVDC asynchronous interconnection has better short circuit current limiting effect and higher safety and reliability. The effectiveness and superiority of the scheme in short-circuit current limiting is verified.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司