王建元,张峥.基于注入信号与小波能量的小电流接地故障选线研究[J].电测与仪表,2018,55(5):28-32.
wangjianyuan,zhangzheng.Research of Fault Line Selection in Small Current Grounding System Based on Injected Signal and Wavelet Energy[J].Electrical Measurement & Instrumentation,2018,55(5):28-32.
基于注入信号与小波能量的小电流接地故障选线研究
Research of Fault Line Selection in Small Current Grounding System Based on Injected Signal and Wavelet Energy
DOI:
中文关键词:  小电流接地系统  注入法  小波能量法  过渡电阻
英文关键词:small current grounding system, injection method, wavelet energy method, transition resistance
基金项目:
     
作者中文名作者英文名单位
王建元wangjianyuan东北电力大学
张峥zhangzheng东北电力大学
摘要点击次数: 2034
中文摘要:
      摘要:为了解决当小电流接地系统发生单相高阻接地时传统注入法因信号分流无法正确选线的问题,在详细分析了注入法及小波能量法选线的原理后,本文提出了一种将两者结合的配电网故障选线新方法。首先向发生故障的系统中注入220Hz特殊频率的信号;对从各条线路中所提取的注入电流展开小波变换;接着使用所得出的小波系数计算小波低频能量;最后通过比较各馈线注入信号能量的大小选线。利用Simulink搭建系统模型并进行仿真实验,其结果可知,虽然故障点距离、故障合闸角大小、中性点接地方式等因素并不能影响新方法的正确选线,但过渡电阻较大时依然选线失败,通过相位比较或图像识别等方法仍能很好的解决此问题,从而大幅提升了注入法选线的正确率。
英文摘要:
      Abstract:In order to solve the problem that traditional injection method can't select line correctly because of signal sub-flow when single phase high resistance grounding occurs in the small current grounding system,this paper proposes a new method of fault line selection which combines injection method and wavelet energy method for distribution network after analyzing the principle of line selection by the two methods in detail.In this paper the 220Hz special frequency signal was injected into the fault system firstly and the injected signal from every feeders was extracted to be wavelet transformed,then the wavelet low frequency energy was calculated by the wavelet coefficients.Finally the line was selected by comparing the size of energy among the feeders.The study processed simulation experiments trough using the the system model built by Simulink.The result shows that the new method of fault line selection is not affected by the fault distance, the fault angle size and the neutral point grounding mode.Although the line selection is still failed when the transition resistance is larger but the problem can be solved well through phase comparison method or image recognition method,which will improve the accuracy of line selection by the injection method.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司