• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
彭超敏,粟时平,施灵卫,张丰鸣.同相牵引供电系统中无锁相环的电流检测方法研究[J].电测与仪表,2018,55(5):63-69.
pengchaomin,sushiping,silingwei,zhangfengming.single phase current detection method research of cophase traction power supply system[J].Electrical Measurement & Instrumentation,2018,55(5):63-69.
同相牵引供电系统中无锁相环的电流检测方法研究
single phase current detection method research of cophase traction power supply system
DOI:
中文关键词:  相位偏差  均值滤波器  单相锁相环  Scott平衡变压器  同相牵引供电
英文关键词:The phase deviation  The mean filter  Single phase locked loop  Scott balanced transfer  In phase of traction power supply
基金项目:
           
作者中文名作者英文名单位
彭超敏pengchaomin长沙理工大学电力系统安全运行与控制湖南省高校重点实验室
粟时平sushiping长沙理工大学电力系统安全运行与控制湖南省高校重点实验室
施灵卫silingwei长沙理工大学电力系统安全运行与控制湖南省高校重点实验室
张丰鸣zhangfengming长沙理工大学电力系统安全运行与控制湖南省高校重点实验室
摘要点击次数: 2000
中文摘要:
      为了能实时准确的补偿同相铁路其负载侧的基波无功电流与谐波电流,使三相电源侧的功率因数为1,从而达到三相平衡。传统的利用三角函数正交特性,用加法器,乘法器,积分器,锁相环就能实现基波有功电流与无功电流的检测,虽能避免大量的矩阵与反矩阵的运算,使得整个运算电路成本低,方法简单,易于实现,但由于单相锁相环特有的相位延对于锁定电压的相位有偏差,加上低通滤波器固有的延时,严重影响了它的电流初期的检测值。基于上述问题,考虑到均值滤波器特有的快速检测性能,提出一种基于Scott平衡变压器的供电模型的负载基波有功电流与基波无功电流的改良检测方法,用均值滤波器良好的响应速度来替代低通滤波器与单相锁相环锁定被测电压的相位的作用。仿真验证了该方法得准确性与优越性,其获取负载侧的单相基波有功与无功电流及谐波电流效果理想。
英文摘要:
      In order to be real-time and accurate compensation in phase railway the fundamental reactive current and load side harmonic current, make the power factor of three-phase power supply side is 1, so as to achieve three phase equilibrium. Traditional use of orthogonal trigonometric function characteristics, use adder, multiplier, integrator, phase-locked loop can achieve the fundamental active current and reactive current detection, can avoid a lot of matrix and the inverse matrix calculations, make the whole operation circuit of low cost, the method is simple, easy to implement, but as a result of single-phase phase-locked loop characteristic of the phase delay for locking phase of voltage deviation, and low pass filter inherent delay, serious impact on its current initial values. Based on the above problem, considering the average filter characteristic of rapid detection performance, put forward a kind of load balance based on Scott transformer power supply model of the fundamental active current and fundamental reactive current improved detection methods, with average filter good response speed instead of low pass filter and single-phase PLL lock in the phase of the measured voltage. Simulation verify the accuracy and superiority of the method, the load side for single-phase fundamental wave active and reactive current and harmonic current effect is ideal.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司