何廷一,李胜男,吴水军,陈振,郑子萱.大规模风电接入对电力系统暂态稳定风险的影响研究[J].电测与仪表,2017,54(20):.
He Tingyi,Li Shengnan,Wu Shuijun,Chen Zhen,Zheng Zixuan.Study on the influence of large-scale wind power integration onpower system transient stability risk[J].Electrical Measurement & Instrumentation,2017,54(20):.
大规模风电接入对电力系统暂态稳定风险的影响研究
Study on the influence of large-scale wind power integration onpower system transient stability risk
DOI:
中文关键词:  大规模风电  并网  故障严重程度  暂态稳定  效用理论  风险评估
英文关键词:large-scale  wind farm, grid  interconnection, failure  severity, transient  stability, utility  theory, risk  assessment
基金项目:
              
作者中文名作者英文名单位
何廷一He Tingyi云南电力科学研究院
李胜男Li Shengnan云南电力科学研究院
吴水军Wu Shuijun云南电力试验研究院有限公司
陈振Chen Zhen四川大学 电气信息学院
郑子萱Zheng Zixuan四川大学 电气信息学院
摘要点击次数: 2514
中文摘要:
      大规模风电接入电网可能影响电网运行状态,造成系统暂态稳定特性改变,量化大规模风电接入对电力系统暂态稳定风险的影响,是保证风电消纳和电网安全的重要课题。在研究系统暂态稳定性分析中的风电模型和电网故障严重程度的基础上,提出一种评估大规模风电接入的电力系统暂态稳定风险评估方法。该方法充分计及风电出力与系统故障状态的随机性,并基于效用理论,以调度员对功角偏差的感知效用为度量指标,建立用非线性效用函数量化故障的严重程度,同时对系统暂态稳定风险指标的计算方法与流程进行了详细研究。将该方法应用于新英格兰39节点系统,对比研究了不同并网容量和并网点对暂态稳定风险的影响,仿真结果证明了所提方法的正确性和有效性。
英文摘要:
      The integration of large-scale wind farms would influence the operation status of power system, which results in the change of transient stability characteristic, so that it is very important to quantify the impact of wind farms for ensuring the wind power using and power system security. The power system transient stability risk assessment method considering large-scale wind farms is proposed in this paper based on the research of wind power model and failure severity. Based on the consideration of the randomness of wind farm outputs and system failure states, the method employ the utility theory and take the perceived utility of operator to relative angle deviation as the measure index, then the nonlinear utility function is constructed to quantify the fault severity. Further, the calculation method and flow chart of power system transient stability index are also provided in detail. This method is applied to the New England 39-bus system, and the effect of different integration capacity and different integration point on system transient stability risk value is investigated. The simulation results show the effectiveness of the proposed method.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司