张骥,张金锋,朱能富,余娟,陈子亮.基于改进深度学习的刀闸状态识别方法研究[J].电测与仪表,2018,55(5):8-13.
Zhang Ji,Zhang Jinfeng,Zhu Nengfu,Yu Juan,Chen Ziliang.The switch state recognition method based on improved deep learning[J].Electrical Measurement & Instrumentation,2018,55(5):8-13.
基于改进深度学习的刀闸状态识别方法研究
The switch state recognition method based on improved deep learning
DOI:
中文关键词:  卷积神经网络  深度学习  绝缘子检测  刀闸状态识别
英文关键词:convolutional neural networks, deep learning, insulators location, switch state recognition
基金项目:国家电网公司科技项目(5212D01502DB)
              
作者中文名作者英文名单位
张骥Zhang Ji国电南瑞科技股份有限公司
张金锋Zhang Jinfeng国网安徽省电力公司建设部
朱能富Zhu Nengfu国电南瑞科技股份有限公司
余娟Yu Juan国电南瑞科技股份有限公司
陈子亮Chen Ziliang安徽大学电子信息工程学院
摘要点击次数: 2500
中文摘要:
      识别刀闸状态对于现代电力系统至关重要,传统的刀闸状态识别方法不能很好地解决多刀闸目标干扰问题。为了解决该问题,本文提出了一种基于改进深度学习的刀闸状态识别方法。首先雇佣空间加权的池化策略来改进传统的卷积神经网络(CNNs);其次利用改进CNNs在训练数据库上获得训练模型;然后通过训练模型来检测绝缘子和刀闸的潜在位置,并进一步利用非极大值抑制和直线拟合算法获得精确的绝缘子和刀闸位置;最后利用与绝缘子的连通性和刀闸区域的长宽比来识别多刀闸的闭合或断开状态。实验结果表明该方法能够精确地定位绝缘子和刀闸的位置,显著提高刀闸状态识别的精度。
英文摘要:
      The switch state recognition is essential for modern power systems, and traditional switch state recognition methods cannot effectively solve the problem of multiple switch target interference. In order to solve the problem, a switch state recognition method based on improved deep learning was proposed. Firstly, a spatially weighted pooling strategy was employed to improve traditional convolutional neural networks (CNNs). Secondly, the model was trained on the training database by using the improved CNNs. Thirdly, the trained model was used to detect the candidate positions of insulators and switches, and then the exactly locations of insulators and switches were extracted via non-maximum suppression algorithm and line fitting method. Finally, the on/off state of switches was recognized by calculating length-width ratio of switch regions and connectivity between switch region and insulator regions. The experiment results show that the proposed method can accurately localize the insulators, switches and significantly improve the precision of recognizing switch state.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司