傅裕斌,段拴峰,曹玉胜,樊友平.风电场与电铁同母线接入对供电质量的影响研究[J].电测与仪表,2018,55(12):01-06.
FU Yubin,Duan ShuanFeng,CAO Yusheng,FAN Youping.Power Quality Study on the Bus linked withWind Farm and Electric Railway[J].Electrical Measurement & Instrumentation,2018,55(12):01-06.
风电场与电铁同母线接入对供电质量的影响研究
Power Quality Study on the Bus linked withWind Farm and Electric Railway
DOI:
中文关键词:  风电场  牵引负荷  电能质量  EMTP-RV
英文关键词:Wind Farm  Traction load  Power Qulitiy  EMTP-RV
基金项目:
           
作者中文名作者英文名单位
傅裕斌FU Yubin武汉大学 电气工程学院
段拴峰Duan ShuanFeng广西送变电勘察设计有限公司
曹玉胜CAO Yusheng武汉大学电气工程学院
樊友平FAN Youping武汉大学电气工程学院
摘要点击次数: 1830
中文摘要:
      本文基于实际工程,借助电磁暂态仿真软件EMTP-RV建立了广西灵川县海洋风电场的详细仿真模型,和与风电场接入同一变电站110kV母线的灵川电铁牵引站及机车负荷模型。研究了风电场在不同风速出力和电铁负荷状态下公共接入点电能质量,以及风电场与电铁牵引负荷接入同一110kV母线的相互影响。并开发了电能质量计算模板用于多种电能质量指标的计算。多种运行工况的仿真表明,风电场与电铁负荷接入同一母线会恶化电网的运行条件,导致公共接入点剧烈电压波动,并向公共电网注入大量谐波。针对仿真中揭示的电压波动与功率振荡现象,本文结合现场条件,针对性提出合理调度风电出力、谐波治理与无功补偿等多项改善措施,使接入点电能质量满足国家标准。
英文摘要:
      Based on a real engineering project, by means of electromagnetic transient simulation software EMTP-RV, a detailed simulation of the Lingtian wind farm in Lingchuan County,Guangxi Province has been modelled, and the electric railway Lingchuan traction station with locomotive load model is connected to the wind farm on the same 110kV bus. Multiple operating conditions such as wind farm with different wind speed and different electric railway load simultaneously connecting to the same substation 110kV bus, are simulated and analysed. A power quality calculation template is developed, and the corresponding power quality indexes are calculated. The simulation results show that the wind farm and electric railway load connected to the same bus will deteriorate the operating conditions of the grid PCC, and cause extremely voltage fluctuation and harmonic injection. Combining with field conditions, a number of improvement advises are put forward from the voltage fluctuation and the power oscillation phenomenon revealed by the simulation, such as: a reasonable scheduling of wind farm active reactive power output, adding harmonic compensation device at electric traction station, set up SVG reactive power compensation automatic control system at 110kV substation. After that, the improved PCC power quality will fulfil the national standards.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司