黄晶晶,唐文虎,周九江,辛妍丽.基于纳秒级IFRA方法的变压器绕组变形检测研究[J].电测与仪表,2018,55(1):6-13.
Huang Jingjing,Tang Wenhu,Zhou Jiujiang,Xin Yanli.Investigation of Nanosecond Impulse Frequency Response Analysis System for Power Transformer Winding Displacement Detection[J].Electrical Measurement & Instrumentation,2018,55(1):6-13.
基于纳秒级IFRA方法的变压器绕组变形检测研究
Investigation of Nanosecond Impulse Frequency Response Analysis System for Power Transformer Winding Displacement Detection
DOI:
中文关键词:  绕组变形  频率响应分析法  纳秒级脉冲
英文关键词:transformer  winding displacement  frequency response analysis  nanosecond impulse
基金项目:国家自然科学基金(51477054);国家高技术研究发展计划项目(863计划)(2015AA050201)
           
作者中文名作者英文名单位
黄晶晶Huang Jingjing华南理工大学
唐文虎Tang Wenhu华南理工大学
周九江Zhou Jiujiang华南理工大学
辛妍丽Xin Yanli华南理工大学
摘要点击次数: 1850
中文摘要:
      脉冲频率响应分析法(IFRA)相比广泛应用于离线检测的扫描频率响应分析法(SFRA)在变压器绕组在线监测中有更好的适用性。目前,离线IFRA方法的激励脉冲波形特征尚未标准化,其可靠性、灵敏性、重复性需要深入研究。本文通过实验提取了适合于变压器绕组变形IFRA检测的激励脉冲波形特征,采用分频段分层小波阈值去噪提取IFRA频响曲线。在一台配电变压器上模拟了三种程度的轴向绕组变形,在两种接线方式下,均依次用IFRA方法和SFRA方法进行检测,并用斯皮尔曼相关系数和欧式距离对IFRA频响曲线进行量化分析,验证了纳秒级IFRA方法的可靠性和灵敏性,并进行了重复性验证。
英文摘要:
      A large amount of studies have shown that compared with sweep frequency response analysis (SFRA), impulse frequency response (IFRA) is feasible for online condition monitoring of power transformer winding deformation, but nowadays even offline IFRA still has many drawbacks, e.g., the features of the injected impulse is not standardized and the sensitivity, reliability and reproducibility of IFRA is in question. In this paper, the features of impulses suitable for IFRA is extracted,and a novel denoising method based on threshold wavelet denoising is designed to extract appropriate IFRA response curves. Three levels of axial displacements were experimentally simulated on a distribution transformer. Both the IFRA system and a commercial SFRA analyzer were applied to obtain the frequency responses of the trans-former at each fault level. Both the IFRA and SFRA measurement are conducted twice with two different connection schemes. Correlation Coefficient and Euclidean Distance are employed for the interpretation of IFRA frequency responses. The reliability, reproducibility and sensitivity of the developed IFRA system is verified through experimental studies.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司