蔡春元,李昕锐,李红斌,彭昭煌,陈劲游,焦洋.10 kV高压电能计量装置电压互感器杂散电容对高压熔断器的影响研究[J].电测与仪表,2018,55(16):13-18.
Cai Chunyuan,Li Xinrui,Li Hongbin,Peng Zhaohuang,Chen Jingyou,Jiao Yang.Research on the effect of a TV’s stray capacitance on the high voltage fuse in 10 kV high voltage electric energy metering device[J].Electrical Measurement & Instrumentation,2018,55(16):13-18.
10 kV高压电能计量装置电压互感器杂散电容对高压熔断器的影响研究
Research on the effect of a TV’s stray capacitance on the high voltage fuse in 10 kV high voltage electric energy metering device
DOI:
中文关键词:  电压互感器  杂散电容  高压熔断器  过电流  电磁暂态仿真
英文关键词:voltage transformer, stray capacitance, high voltage fuses, overcurrent, electromagnetic transient simulation
基金项目:
                 
作者中文名作者英文名单位
蔡春元Cai Chunyuan广东电网有限责任公司 中山供电局计量中心
李昕锐Li Xinrui华中科技大学 电气与电子工程学院
李红斌Li Hongbin华中科技大学 电气与电子工程学院
彭昭煌Peng Zhaohuang广东电网有限责任公司 中山供电局计量中心
陈劲游Chen Jingyou广东电网有限责任公司 中山供电局计量中心
焦洋Jiao Yang华中科技大学 电气与电子工程学院
摘要点击次数: 1478
中文摘要:
      高压电能计量装置是10kV配网的重要组成部分,但在其运行过程中,电压互感器支路上熔断器的异常动作时有发生,危及电网安全。本文针对电压互感器V形接线方式,以互感器的传感原理为基础,从幅值和频率两方面探讨了支路过流的可能,并提出真空断路器动作时,由互感器杂散电容引起的安培以上量级过电流是高压熔断器异常动作的关键诱因;然后,借助Ansoft Maxwell和ATP-EMTP软件,完成了杂散参数的求解和仿真模型的搭建,并以真空断路器的动作为例,计及三相非同期性,研究了不同合闸情况下的互感器支路过流情况;最后,针对非同期性和杂散电容带来的过流问题,提出并仿真验证了基于合闸同期性控制和杂散电容控制的支路过流抑制措施,可降低熔断器的异常动作风险,对高压电能计量装置的可靠性提升具有指导意义。
英文摘要:
      The HV electric energy measuring device is an important part of 10kV distribution network, but the fuse in a transformer branch often malfunctions, endangering the safety of grid. Based on the principle of TV, this paper focuses on the overcurrent causing by the increasing of signals’ amplitude and frequency when 2 TVs are connected with the V method. That the current caused by stray capacitance of TV is greater than 1A is the key inducement for high voltage fuses to malfunction when vacuum circuit breaker action is proposed. Then, Ansoft Maxwell and ATP-EMTP are respectively used to calculate the stray parameters and to build the simulation model. During the vacuum circuit breaker’s operation, with three-phase asynchronism being taken into account, overcurrent under different circumstances are analyzed. Finally, measures based on the control of asynchronism and stray capacitance are taken to suppress overcurrent, which can reduce risks of a fuse’s malfunction and is of significance in improving the reliability of HV electric energy measuring device.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司