• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
丁敏华,姜干才,徐胜光,杨达亮,吴宁.新型无锁相环DSTATCOM直接电流控制方法[J].电测与仪表,2017,54(24):.
DING MINHUA,JIANG GANCAI,XU SHENGGUANG,YANG DALIANG,WU NING.A novel direct current control method for DSTATCOM without PLL[J].Electrical Measurement & Instrumentation,2017,54(24):.
新型无锁相环DSTATCOM直接电流控制方法
A novel direct current control method for DSTATCOM without PLL
DOI:
中文关键词:  配电网静止同步补偿器  锁相环  矢量控制  直接电流控制
英文关键词:distribution network static synchronous compensator (DSTATCOM)  phase-locked loop (PLL)  vector control  direct current control
基金项目:
              
作者中文名作者英文名单位
丁敏华DING MINHUA杭州炬华科技股份有限公司
姜干才JIANG GANCAI杭州炬华科技股份有限公司
徐胜光XU SHENGGUANG广西大学
杨达亮YANG DALIANG广西大学
吴宁WU NING广西大学
摘要点击次数: 1880
中文摘要:
      传统DSTATCOM直接电流控制方法依赖锁相环和坐标变换,实现较为复杂,本文提出一种新型无锁相环的DSTATCOM直接电流控制方法。通过建立DSTATCOM数学模型,依据矢量等效原理计算出配电网电压有功单位分量和无功单位分量,无需锁相环和坐标变换便可实现无功补偿控制。仿真验证了该方法的可行性。采用 DSP 控制器TMS320F2812和智能功率模块PM300DVA120,搭建了DSTATCOM系统实验平台,在开关频率10kHz、死区时间4μs下获得良好的实验结果。所提方法物理意义清晰且易于嵌入式控制器实现。实验结果表明,所提方法能实现输出电流超前滞后电压的无功补偿实时控制,具有良好的动静态响应性能。
英文摘要:
      Conventional DSTATCOM direct current control method needs phase-locked loop (PLL) and coordinate transformation, making it difficult to implementation. A novel direct current control method for DSTATCOM without PLL is proposed in this paper. By establishing the mathematical model of DSTATCOM,the active power unit component and reactive power unit component of the distribution network voltage are calculated based on the principle of vector equivalence,and the reactive power compensation control can be realized without PLL or coordinate transformation.The novel control method is proved feasible by the MATLAB/Simulink simulation results. The DSTATCOM system experimental platform is established using DSP TMS320F2812 controller and intelligent power module(IPM) PM300DVA120, the experimental results are excellent when the switching frequency is 10 kHz and the dead time is 4μs.The proposed method in this paper has a clear physical meaning and is easy to be realized with embedded controller. The experimental results indicate that the proposed method can realize the flexible reactive power compensation control of the output current lead-lag voltage and has good dynamic and static response performance.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司