汪佛池,周若琪,张鹏,沈海滨,律方成.配电变压器雷击建模及雷电防护[J].电测与仪表,2018,55(20):15-21.
Wang Fochi,Zhou Ruoqi,Zhang Peng,Shen Haibin,Lv Fangcheng.Lightning Stroke Modeling and Lightning Protection of Distribution Transformers[J].Electrical Measurement & Instrumentation,2018,55(20):15-21.
配电变压器雷击建模及雷电防护
Lightning Stroke Modeling and Lightning Protection of Distribution Transformers
DOI:
中文关键词:  配电变压器  散射参数  雷击建模  冲击电晕  雷电防护
英文关键词:distribution transformers  scattering parameter  lightning stroke model  impulse corona  lightning protection  
基金项目:河北省自然科学基金
              
作者中文名作者英文名单位
汪佛池Wang Fochi华北电力大学河北省输变电设备安全防御重点实验室
周若琪Zhou Ruoqi华北电力大学河北省输变电设备安全防御重点实验室
张鹏Zhang Peng华北电力大学河北省输变电设备安全防御重点实验室
沈海滨Shen Haibin中国电力科学技术研究院 北京市海淀区
律方成Lv Fangcheng华北电力大学河北省输变电设备安全防御重点实验室
摘要点击次数: 1746
中文摘要:
      配电变压器(简称配变)作为配网的重要组成部分,绝缘水平低,易遭受雷电过电压的侵害,其安全运行对配电网稳定性及可靠性具有十分重要的意义。本文采用散射参数测量法,测量配变散射参数并经数据处理获得配变的阻抗幅频特性,经电路拟合构建了适用于雷击情况的配变宽频模型,并经基于模拟退火法的粒子群算法对等效电路参数进行进一步优化,实测结果表明配变实际输出响应与本文宽频模型仿真结果吻合度较高。基于该宽频模型分析了冲击电晕对配变过电压传播的影响以及配变防雷保护措施,结果表明冲击电晕显著减小配变过电压幅值,配变低压侧加装避雷器对其防雷作用明显。
英文摘要:
      As an important part of distribution network, distribution transformer(DT)has low insulation level and is vulnerable to lightning overvoltage. The safe operation of distribution transformer is very important to the stability and reliability of distribution network. In this paper, the scattering parameter measurement method is used to establish distribution transformer model, amplitude frequency characteristics is obtained by impedance measurement and data processing of distribution transformer circuit fitting and particle swarm optimization algorithm based on simulated annealing is intriduced to optimize the model. The measured results show that the measurement results of the distribution transformer under lightning stroke are in good agreement with the simulation results established in this paper. Based on the broadband model, the influence of shock corona on voltage distribution of distribution transformer and the lightning protection measures of distribution transformer are analyzed.The results show that the shock corona significantly reduces the amplitude of the transformer over voltage,and the lightning protection effect of lightning arrester installed on the low voltage side of the transformer substation is obvious.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司