• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
陈刚,胡琛,焦洋,杨世海,赵双双.非均匀空心线圈偏心误差建模研究[J].电测与仪表,2018,55(19):27-33.
Chen Gang,Hu Chen,Jiao Yang,Yang Shihai,Zhao Shuangshuang.Modeling of the eccentricity error of air-core coil with uneven turns[J].Electrical Measurement & Instrumentation,2018,55(19):27-33.
非均匀空心线圈偏心误差建模研究
Modeling of the eccentricity error of air-core coil with uneven turns
DOI:
中文关键词:  空心线圈  偏心误差  偏心距离  不均匀度  相对位置
英文关键词:air-core coil  eccentricity error  off-center distance  inhomogeneity  relative position
基金项目:
              
作者中文名作者英文名单位
陈刚Chen Gang国网江苏省电力公司电力科学研究院
胡琛Hu Chen华中科技大学
焦洋Jiao Yang华中科技大学
杨世海Yang Shihai国网江苏省电力公司电力科学研究院
赵双双Zhao Shuangshuang国网江苏省电力公司电力科学研究院
摘要点击次数: 1873
中文摘要:
      空心线圈的偏心误差关乎智能变电站的安全稳定运行以及电能的可靠计量。以往研究多集中于均匀空心线圈的偏心误差,对非均匀空心线圈的偏心误差研究不够深入。建立均匀和非均匀空心线圈的偏心误差模型,分析了互感系数和偏心距离、不均匀度、相对位置以及线圈结构等影响因素的关系,仿真结果表明了当载流体不偏心时,不均匀度不会影响偏心误差;当载流体偏心达到线圈内径的1/4时,不均匀度仅有0.5°时便足以造成10%的互感系数误差。对3个不同参数的空心线圈进行了准确度试验,试验结果表明当偏心距离小于4mm,空心线圈比差不超过0.2%。偏心距离变化至16 mm,空心线圈比差的将超过了1%。空心线圈的角差不受偏心距离的影响。
英文摘要:
      Eccentricity error of air-core coil is of great importance to the stability and safety of smart substations, as well as the reliable metering of electrical energy. Previous research has been mostly conducted on air-core coil with even turns. On the contrary, few studies have been done on air-core coil with uneven turns. This paper modeled the eccentricity error of air-core coil with even turns and uneven turns, respectively. The relationships between the mutual inductance and off-center distance, inhomogeneity, relative position, geometrical parameters were examined. The simulation results show that the eccentricity error will not be influenced by the inhomogeneity when the current-carrying conductor is centered. However, the error will be up to 10% under the condition of 0.5° inhomogeneity and off-center distance of one quarter of coil inner radius. The experiments on the accuracy of three designed air-core coils with respect to off-center distance was carried out. The experimental results show that when the off-center distance is less than 4 mm, the ratio error will be less than 0.2%。 And when the distance reaches 16 mm, the error will exceed 1%. to 32 mm. On the other hand, the phase difference remains almost unchanged during the experiments.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司