• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
陈忠,季坤,罗沙,张俊杰,程登峰,操松元.大容量直流融冰兼网省协调无功补偿装置的集成与应用[J].电测与仪表,2018,55(20):137-141.
Chen Zhong,Ji Kun,Luo Sha,Zhang Junjie,Cheng Dengfeng,Cao Songyuan.The integration and application of large capacity DC ice melting and static var compensation device with network provincial coordination[J].Electrical Measurement & Instrumentation,2018,55(20):137-141.
大容量直流融冰兼网省协调无功补偿装置的集成与应用
The integration and application of large capacity DC ice melting and static var compensation device with network provincial coordination
DOI:
中文关键词:  大容量  直流融冰  静止无功补偿  500kV变电站  AVC
英文关键词:large  capacity, DC  ice melting, Static  Var Compensation, 500kV  station, AVC
基金项目:
                 
作者中文名作者英文名单位
陈忠Chen Zhong国网安徽省电力公司电力科学研究院
季坤Ji Kun国网安徽省电力公司
罗沙Luo Sha国网安徽省电力公司
张俊杰Zhang Junjie国网安徽省电力公司检修公司
程登峰Cheng Dengfeng国网安徽省电力公司电力科学研究院
操松元Cao Songyuan国网安徽省电力公司
摘要点击次数: 1906
中文摘要:
      500kV官山变固定式直流融冰兼无功补偿装置主电路为无换流变的6脉波桥式拓扑,网侧电抗器采用油浸式铁心结构,兼作无功补偿模式下的相控电抗器。该装置在无功补偿模式下直接接入华东网调电压自动控制系统,接受无功指令调度运行。本文介绍了该套装置的基本参数、拓扑重构方案、融冰线路切换系统、无功网省协调机制。给出了典型运行模式下的控制策略,并且结合现场运行数据对该套装置在架空输电线路融冰、无功补偿方面的应用效果进行了分析。
英文摘要:
      The main circuit topology of fixed DC ice melting and reactive power compensation device in 500kV Guanshan station is a 6-pulse bridge without converter transformer. The type of grid-side reactor is oil-filled iron core, also serves as phase controlled reactor in reactive power compensation mode. The device is direct accessed by the automatic voltage control system of East China Grid company, accepts scheduled command during reactive power compensation mode. The basic parameters, topology reconstruction scheme, ice melting line switching system, reactive coordination mechanism between East China Grid company and provincial grid company is introduced in this paper. The control scheme in typical operating mode is also described, and combined with field operating data, the effect of the device in overhead power transmission lines ice melting and reactive power compensation are analyzed.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司