• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
邵尤国,李辉,赵洁,邹建明,周晓刚,常强.山火条件下的特高压输电线路击穿概率模型研究与分析[J].电测与仪表,2018,55(21):31-35,42.
Shao Youguo,Li Hui,Zhao Jie,Zou Jianming,Zhou Xiaogang,Chang Qiang.Study and Analysis of Breakdown Probability Model of UHV Transmission Line under Forest Fire Condition[J].Electrical Measurement & Instrumentation,2018,55(21):31-35,42.
山火条件下的特高压输电线路击穿概率模型研究与分析
Study and Analysis of Breakdown Probability Model of UHV Transmission Line under Forest Fire Condition
DOI:
中文关键词:  特高压  输电线路  山火  击穿概率
英文关键词:UHV  transmission line  forest fire  breakdown probability
基金项目:
                 
作者中文名作者英文名单位
邵尤国Shao Youguo武汉大学电气工程学院
李辉Li Hui国家电网公司华中分部
赵洁Zhao Jie武汉大学电气工程学院
邹建明Zou Jianming国家电网公司华中分部
周晓刚Zhou Xiaogang国家电网公司华中分部
常强Chang Qiang湖北华中电力科技开发有限责任公司
摘要点击次数: 1678
中文摘要:
      特高压输电线路跨越林区、秸秆类农作物,山火的发生会威胁系统运行可靠性和稳定性。综合考虑了山火温度和燃烧产生的碳化小颗粒、灰烬浓烟对输电线路气隙绝缘强度影响,并将山火高度作为气隙击穿电压修正因素,建立了山火条件下的特高压输电线路击穿概率计算模型。仿真结果表明山火条件下特高压相地、相间击穿概率随温度、烟浓度呈现“S”型增长态势;山火高度对相地气隙绝缘强度影响类似于温度因素。且相同山火条件下,特高压相地击穿概率远低于超高压;相同烟浓度下,特高压更易发生相间击穿,但由于相同山火条件下的特高压相间烟浓度更低,其实际相间击穿概率可能低于超高压。
英文摘要:
      Ultra high voltage(UHV) transmission lines across forest areas and straw crops, and the occurrence of wiforest fire threats the reliability and stability of the power system. Considering the influence of the fire temperature and the carbonized small particles, ashes and smoke on the air gap insulation of transmission line, and the height of wildfires is taken as the correction factor of air gap breakdown voltage, the calculation model of breakdown probability of UHV transmission line under the condition of mountain fire is established then. The simulation results show that the breakdown probability of UHV exhibits a "S" growth pattern with temperature and smoke density. And the effect of fire height on insulation of the air gap is similar to that of temperature. Under the same fire condition, the phase-to-ground breakdown probability of UHV is much lower than that of Extra high voltage(EHV). At the same smoke density, the phase-to-phase breakdown is more likely to occur at UHV. But because of the lower smoke density under the same fire condition, the actual situation may be opposite.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司