陈中,殷大朋,朱英凯,周涛,施志强.虚拟惯性时间常数对互联电网小干扰稳定影响研究[J].电测与仪表,2018,55(22):1-6.
Chen Zhong,Yin Dapeng,Zhu Yingkai,Zhao Tao,Shi Zhiqiang.Research of Influence of Virtual Inertia Time Constant on Interconnected Power System Small Disturbance Stability[J].Electrical Measurement & Instrumentation,2018,55(22):1-6.
虚拟惯性时间常数对互联电网小干扰稳定影响研究
Research of Influence of Virtual Inertia Time Constant on Interconnected Power System Small Disturbance Stability
DOI:
中文关键词:  小干扰稳定  互联交流电网  惯性时间常数  特征分析法  虚拟同步发电机
英文关键词:small disturbance stability, interconnected AC power grid  inertial time constant  eigenvalue analysis method  virtual synchronous generator
基金项目:国家重点研发计划资助项目(2016YFB0900602),国家自然科学基金资助项目(51277029),江苏省智能电网技术与装备重点实验室课题资助
              
作者中文名作者英文名单位
陈中Chen Zhong东南大学 电气工程学院
殷大朋Yin Dapeng东南大学 电气工程学院
朱英凯Zhu Yingkai南京供电公司
周涛Zhao Tao东南大学 电气工程学院
施志强Shi Zhiqiang东南大学 电气工程学院
摘要点击次数: 1554
中文摘要:
      传统同步发电机的惯性时间常数是不变的物理参数,虚拟同步发电机的推广与应用使得系统惯性时间常数具有可变性和可调性,继而有可能影响互联系统的小干扰稳定性。论文以VSC-HVDC为研究对象,对其进行虚拟同步发电机控制建模,然后基于特征分析法,对等值联网系统求解低频振荡衰减因子的解析表达式,分析了不同场景下惯性时间常数对小干扰稳定水平的影响程度,发现当惯性时间常数与阻尼系数在同一个数量级时对小干扰稳定有较大影响。最后在两区四机经典模型中验证了结论,对于虚拟同步发电机参数整定和研究互联系统的小干扰稳定性分析及控制具有一定的参考价值。
英文摘要:
      In the traditional power system, the inertia time constant of a synchronous generator is an invariant physical parameter. However, with the application and popularization of the virtual synchronous generators, the inertia time constant of the system becomes variable and adjustable, which may affect the small disturbance stability of the interconnected system. VSC-HVDC is taken as the research object and the virtual synchronous generator control is built on it. Then, based on the eigenvalue analysis method, the analytic expression of the low-frequency oscillation attenuation factor for the equivalent networking system is solved, and the degree of influence of the inertial time constant on the stability level of small disturbance is analyzed. In the proposed method, the inertia time constant has a great influence on the small disturbance stability when being in the same order of magnitude with damping coefficient. Finally, the influence of the inertia time constant on the regional low frequency oscillation mode is verified in the classical model of 2-area 4-generator, which has certain reference value for the analysis and control of the regional small disturbance stability of the interconnected power system and the virtual synchronous generator parameter setting.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司