陈少帅,刘云鹏,黄世龙,周广洋,张重远.高海拔下特高压交流同塔双回输电线路导线电晕损失研究[J].电测与仪表,2019,56(3):29-34.
Chen Shaoshuai,Liu Yunpeng,Huang Shilong,Zhou Guangyang,Zhang Zhongyuan.The Study of Corona Loss of UHV AC Double circuit transmission line on the same towerat High Altitude Area[J].Electrical Measurement & Instrumentation,2019,56(3):29-34.
高海拔下特高压交流同塔双回输电线路导线电晕损失研究
The Study of Corona Loss of UHV AC Double circuit transmission line on the same towerat High Altitude Area
DOI:
中文关键词:  高海拔  电晕笼  电晕损失  交流特高压  同塔双回输电
英文关键词:high altitude  corona cage  corona loss  AC UHV  Double circuit transmission on the same tower
基金项目:
              
作者中文名作者英文名单位
陈少帅Chen Shaoshuai华北电力大学河北省输变电设备安全防御重点实验室;国网河北省电力公司检修分公司
刘云鹏Liu Yunpeng华北电力大学河北省输变电设备安全防御重点实验室;华北电力大学新能源电力系统国家重点实验室
黄世龙Huang Shilong华北电力大学
周广洋Zhou Guangyang华北电力大学河北省输变电设备安全防御重点实验室
张重远Zhang Zhongyuan华北电力大学河北省输变电设备安全防御重点实验室
摘要点击次数: 2193
中文摘要:
      针对目前我国特高压交流同塔双回输电常用的8×LGJ-630/45导线,基于在西宁市平安县(2200m)搭建的特高压电晕笼,系统的研究了8×LGJ-630/45导线在干燥、中雨(6mm/h)、大雨(12mm/h)及湿导线的条件下的电晕损失,首次获得了实际高海拔点8×LGJ-630/45导线的电晕笼电晕数据。并以1000kV特高压交流同塔双回输电工程典型塔型为例,通过有限元计算软件仿真计算电晕笼内导线和实际线路导线表面电场强度,采用电晕损失等效法,计算了在高海拔地区导线的电晕损失,获得了同塔双回输电线路的电晕损失数据。为我国将来在高海拔地区建设特高压交流输电线路导线选型提供了参考依据。
英文摘要:
      The research on corona loss in high altitude area of 8×LGJ-630 conductor which is commonly used in UHV AC double circuit transmission in the same tower is studied in this paper based on the UHV corona cage built in the Ping An county(2200m), Xining City.The test conditionincludes dryness, moderate rain(6mm/h),heavy rain(12mm/h)and humidity.For the first time, the corona data of 8×LGJ-630/45 conductors in the corona cage at high altitude were obtained. Then throughfinite element method simulation calculating the electric field intensity of the corona cage wire and the actual line conductor, the corona loss of UHV AC double circuit transmission line in high altitude area is analyzed by the example of typical tower type of 1000kV UHV AC double circuit transmission line on the same tower with corona loss equivalent method. the corona data of double circuit transmission lines on the same tower at high altitude were obtained. It provides reference basis for the selection of UHV AC transmission lines in high altitude area in the future.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司