• 设为首页
  • 加入收藏
  • 联系邮箱
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
  • English
站内检索    
 
张 爽,曾雪洋.基于混合H2/H∞控制理论的交直流并联系统机网阻尼协调控制[J].电测与仪表,2018,55(5):57-62.
Zhang Shuang,zengxueyang.A Coordinated Damping Control of Generator and Gird in AC/DC Parallel Power System Based on Mixed H2/H∞ Control Method[J].Electrical Measurement & Instrumentation,2018,55(5):57-62.
基于混合H2/H∞控制理论的交直流并联系统机网阻尼协调控制
A Coordinated Damping Control of Generator and Gird in AC/DC Parallel Power System Based on Mixed H2/H∞ Control Method
DOI:
中文关键词:  交直流并联系统  低频振荡  鲁棒控制  附加阻尼控制;机网协调控制
英文关键词:Parallel AC/DC power system  Low frequency oscillation  Robust control  Supplementary damping control  Coordinated control of generator and gird
基金项目:国家电网公司科技项目(SGNXDK00BGJS1600021)
     
作者中文名作者英文名单位
张 爽Zhang Shuang国网宁夏电力公司电力科学研究院
曾雪洋zengxueyang四川大学电气信息学院
摘要点击次数: 1766
中文摘要:
      针对交直流并联运行系统阻尼不足、存在区域间低频振荡的问题,本文提出一种基于混合H2/H∞控制理论的交直流并联系统的机网阻尼协调控制策略。首先采用最小二乘-旋转不变算法辨识出系统振荡模式和开环降阶模型,结合混合H2/H∞控制理论,在高压直流输电和发电机中设计了附加鲁棒阻尼控制器,该控制器采用线性矩阵不等式的求解方法和输出反馈构造,求解容易,控制器构造简单,具有较强的鲁棒性。最后在PSCAD/EMTDC中搭建四机两区域测试系统,并与传统附加阻尼控制器对比,仿真结果验证了机网阻尼协调控制的有效性、鲁棒性。
英文摘要:
      In light of the low damping and low frequency oscillation problems of AC/DC parallel power system, a coordinated damping control method of generator and gird in AC/DC parallel power system based on mixed H2/H∞ control theory is proposed. Firstly, system oscillation model and open-loop reduced order model are identified by the total least squares-estimation of signal parameters via rotational invariance techniques(TLS-ESPRIT) algorithm. Combining H2/H∞ control theory and adopting the solution method of linear matrix inequalities and the output feedback structure, the supplementary robust damping controllers of high voltage direct current(HVDC) and generator is designed, whose advantages are easy to be solved, with simple construct of controller, and having strong robustness. In the end, a four machine in two domains test system is built in PSCAD/EMTDC, and compared with the traditional additional damping controller, the simulation results verify the effectiveness and robustness of the coordinated damping control of generator and gird.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司