李卫国,王旭光,卢广旗,许文文.基于DOST能量相似度的有源配电网故障区间定位方法[J].电测与仪表,2019,56(6):50-55.
Li Weiguo,Wang Xuguang,Lu Guangqi,Xu Wenwen.A Fault Section Location Method for Active Distribution Network Based on Discrete Orthogonal S-transform and Energy Similarity[J].Electrical Measurement & Instrumentation,2019,56(6):50-55.
基于DOST能量相似度的有源配电网故障区间定位方法
A Fault Section Location Method for Active Distribution Network Based on Discrete Orthogonal S-transform and Energy Similarity
DOI:
中文关键词:  有源配电网  故障区间定位  离散正交S变换  能量相似度
英文关键词:active  distribution network, fault  section location, discrete  orthogonal S-transform, energy  similarity
基金项目:
           
作者中文名作者英文名单位
李卫国Li Weiguo东北电力大学 电气工程学院 吉林 吉林 132012
王旭光Wang Xuguang东北电力大学 电气工程学院 吉林 吉林 132012
卢广旗Lu Guangqi东北电力大学 电气工程学院 吉林 吉林 132012
许文文Xu Wenwen东北电力大学 电气工程学院 吉林 吉林 132012
摘要点击次数: 1707
中文摘要:
      有源配电网小电流接地系统发生单相接地短路时,通过理论分析得出单个DG接入配电网并不影响零序电流大小的结论,由此提出一种基于离散正交S变换(DOST)暂态零序电流能量相似度的故障定位方法。首先对线路上检测设备上传的暂态零序电流信号进行离散正交S变换,然后利用得到的时频矩阵中的元素计算线路区间两端检测点的能量相似度,能量相似度小于设定的阈值即为故障区间。Matlab/Simulink仿真结果表明该方法准确有效,适用于有源配电网的故障区间定位。
英文摘要:
      When the single-phase to ground short-circuit occurs in the small-current grounding system of the active distribution network, through the theoretical analysis of single DG access to distribution network does not affect the zero sequence current conclusion, so a discrete orthogonal S-Transform (DOST) Fault location method of zero sequence current energy similarity was proposed. Firstly, discrete orthogonal S transform is applied to the transient zero sequence current signal uploaded by the detection equipment on the line, and then the energy similarity of detection points at both ends of the line section is calculated by using the data in the time-frequency matrix obtained, the energy similarity is less than the setting The threshold is the fault interval. The simulation results of Matlab / Simulink show that the method is accurate and effective and can be applied to the fault zone location of active distribution network.
查看全文  查看/发表评论  下载PDF阅读器
关闭
  • 哈尔滨电工仪表研究所有限公司
  • 中国电工仪器仪表信息网
  • 中国仪器仪表学会
  • 中华人民共和国新闻出版总署
  • 中国科技期刊编辑学会
  • 黑龙江省科学技术协会
  • 编辑之家
  • 中国知网
  • 万方数据库
  • 维普网
  • 北极星电力网
  • 中华中控网
  • 网站首页
  • 期刊介绍
    • 期刊简介
    • 历任主编
    • 期刊荣誉
  • 编委会
    • 社长及主编
    • 主任委员
    • 编委名单
  • 投稿指南
    • 作者须知
    • 投稿步骤
    • 范文(规范细则)
    • 稿件处理流程
    • 著作权转让协议
  • 期刊影响力
  • 开放获取
  • 出版道德政策
    • 出版伦理声明
    • 学术不端认定和处理方法
    • 广告及市场推广
    • 同行评议流程
    • 斟误和撤回
    • 回避制度
    • 文章署名及版权转让
  • 历年目次
  • 联系我们
地址:哈尔滨市松北区创新路2000号    邮编:150028
邮箱:dcyb@vip.163.com    电话:0451-86611021;87186023
© 2012 电测与仪表    哈公网监备2301003445号
黑ICP备11006624号-1
技术支持:北京勤云科技发展有限公司